Brocade 100G-Q28-S28-C-01501 Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1.5m (5ft)

Brocade 100G-Q28-S28-C-01501 Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1.5m (5ft)

Use the 100G-Q28-S28-C-01501 compatible assembly where a 100G connection is required between compatible ports. This page covers the 1.5m (5ft) version only, with its own HT part number, specifications and compatibility verification.

OEM Part Number: 100G-Q28-S28-C-01501HT Part Number: 100G-Q28-S28-C-01501

Product Highlights

  • Compatible alternative to Brocade 100G-Q28-S28-C-01501
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to SFP28
  • Fixed length and part number: 1.5m (5ft), 100G-Q28-S28-C-01501
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.125W
  • Minimum bend radius: 60mm

Specifications

HT Part Number100G-Q28-S28-C-01501
Brocade Compatible100G-Q28-S28-C-01501
ManufacturerHT
Form FactorQSFP28 to SFP28
Max Data Rate100Gbps
Cable TypePassive Twinax
Cable Length1.5m (5ft)
Wire AWG30AWG
Minimum Bend Radius60mm
Power Consumption≤0.125W
Power Supply3.3V
MTBF=50 Million Hours
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
MediaCopper
Application100G to 4x 25G Ethernet, Data Centers
ProtocolsIEEE 802.3, QSFP28 MSA, SFF-8665

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

100G-Q28-S28-C-01501 occupies the middle of this family between 100G-Q28-S28-C-0101 at 1m (3ft) and 100G-Q28-S28-C-0201 at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Power and Thermal Planning

The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives 100G-Q28-S28-C-01501 useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Brocade Compatibility and Factory Testing

For this Brocade application, testing combines digital identification with actual traffic-link verification and electrical continuity, link stability and diagnostic readouts. Both ends are inspected for latch, boot and connector damage. If the project uses a specific hardware revision or a channelized port, send those details so that the intended configuration can be reviewed before shipment.

Ordering Information

This product is ordered as 100G-Q28-S28-C-01501 in 1.5m (5ft). Include the equipment model and software release if you would like a pre-order compatibility review. Other lengths use different part numbers and should not be substituted into the same order line.

Frequently Asked Questions

Is this an original Brocade cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 100G-Q28-S28-C-01501.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 1.5m (5ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

What information should I provide for a compatibility check?

Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.

Quality Assurance and Packaging

Every 100G-Q28-S28-C-01501 compatible assembly undergoes link testing, compatibility verification and visual inspection. The 1.5m (5ft) cable is coiled without exceeding its minimum bend radius, fitted with connector protection and packed in an anti-static bag or protective tray before cartoning. Project labels and packing lists are available for volume orders.

Shipping and Lead Time

Lead time for ordinary configurations is normally one to three working days, while production quantities are confirmed with the order. We can arrange express courier or economy freight according to destination and carton volume, or hand the shipment to your appointed logistics provider.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.