Extreme Networks 10GB-C03-SFPP Compatible 10G SFP+ Passive Copper Twinax Cable, 3m (10ft)

Extreme Networks 10GB-C03-SFPP Compatible 10G SFP+ Passive Copper Twinax Cable, 3m (10ft)

The 10GB-C03-SFPP cable offers a direct SFP+ to SFP+ connection at 10Gbps. Its 3m (10ft) length and DAC construction are intended for Extreme Networks equipment, with no separate transceiver-and-patch-cord assembly required.

OEM Part Number: 10GB-C03-SFPPHT Part Number: 10GB-C03-SFPP

Product Highlights

  • Compatible alternative to Extreme Networks 10GB-C03-SFPP
  • 10G connectivity at 10Gbps
  • Interface configuration: SFP+ to SFP+
  • Fixed length and part number: 3m (10ft), 10GB-C03-SFPP
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.1W
  • Minimum bend radius: 23mm

Specifications

HT Part Number10GB-C03-SFPP
Extreme CompatibleSFP-H10GB-CU3m
ManufacturerHT
Connector TypeSFP+ to SFP+
Max Data Rate10Gbps
MediaCopper
Power Supply3.3V
Minimum Bend Radius23mm
Wire AWG30AWG
Cable Length3m (9.84ft)
Jacket MaterialPVC (OFNR)
Cable TypePassive Twinax
Temperature0 to 70°C (32 to 158°F)
Power Consumption≤0.1W
Application10G Ethernet
Protocols1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel

Power and Thermal Planning

The rated power consumption is ≤0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Position Within the Length Range

10GB-C03-SFPP occupies the middle of this family between 10GB-C2.5-SFPP at 2.5m (8ft) and 10GB-C04-SFPP at 4m (13ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 23mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 10G Ethernet. Listed interface and protocol references include 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Extreme Networks Compatibility and Factory Testing

For this Extreme Networks application, testing combines digital identification with actual traffic-link verification and electrical continuity, link stability and diagnostic readouts. Both ends are inspected for latch, boot and connector damage. If the project uses a specific hardware revision or a channelized port, send those details so that the intended configuration can be reviewed before shipment.

Ordering Information

When ordering, specify 10GB-C03-SFPP, cable length 3m (10ft) and the host platform. This allows our team to verify both the physical assembly and the compatibility requirement before production. Neutral labeling and customer packing lists can be arranged for volume orders.

Frequently Asked Questions

Is this an original Extreme Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Extreme Networks 10GB-C03-SFPP.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 3m (10ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

What information should I provide for a compatibility check?

Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.

Quality Assurance and Packaging

Before packing, our team checks the cable jacket, connector boots, latches and identification of each assembly. The cable is then secured in a loose coil and protected against dust and connector impact. Neutral packaging, customer part-number labels and project-specific carton lists can be supplied on request.

Shipping and Lead Time

Available stock is usually packed and handed to the carrier within one to three working days. Delivery can be arranged by international express, air cargo or sea freight, with tracking details supplied after dispatch. Freight-collect shipments and delivery to a customer warehouse or forwarder can also be coordinated.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.