800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G OSFP 2 x 100G PAM4 RHS/Flat Top Passive Copper Breakout Cable, 2m (7ft)

800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G OSFP 2 x 100G PAM4 RHS/Flat Top Passive Copper Breakout Cable, 2m (7ft)

This 2m (7ft) DAC cable is built for multi-vendor equipment requiring the 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FT interface. The 800Gbps link uses 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top) and is supplied as one complete tested assembly.

OEM Part Number: 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FTHT Part Number: 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FT

Product Highlights

  • HT-manufactured DAC assembly in 2m (7ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)
  • Fixed length and part number: 2m (7ft), 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FT
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (800G End)0.1W (200G Per End)
  • Minimum bend radius: 31mm

Specifications

HT Part Number800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FT
ManufacturerHT
Form Factor800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)
Max Data Rate800Gbps
MediaCopper
Cable TypePassive Breakout DAC
Cable Length2m (7ft)
Wire AWG28AWG
Minimum Bend Radius31mm
Max. Power Consumption0.1W (800G End)0.1W (200G Per End)
Jacket MaterialPVC
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, IEEE 802.3ck, CMIS v4.0
Modulation Format8x 100G PAM4 to Quad 2x 100G PAM4

Signal and Lane Configuration

The listed modulation format is 8x 100G PAM4 to Quad 2x 100G PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FT is the longest of 4 verified length options in this family. Compared with 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT at 1.5m (5ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Power and Thermal Planning

The rated power consumption is 0.1W (800G End)0.1W (200G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 31mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Generic Compatibility and Factory Testing

Our compatibility setup for Generic 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FT is checked together with the physical 2m (7ft) assembly. Factory verification covers connector condition, host identification, error-free link establishment and electrical continuity, link stability and diagnostic readouts. Providing the exact host model and firmware release helps us identify platform-specific requirements before production.

Ordering Information

Use part number 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-2M7FT for the 2m (7ft) assembly. For mixed-length projects, list each required part number and quantity separately so that every cable can be tested and packed according to its intended installation.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate optical modules required?

No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 2m (7ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

Quality Assurance and Packaging

Quality control includes connector appearance, cable identification and functional verification. Packing materials are selected to keep the connector housings and cable boots from taking impact during transport, and the coil is not compressed into an undersized bundle. Volume orders can include customer-specific labels and packing documentation.

Shipping and Lead Time

Available stock is usually packed and handed to the carrier within one to three working days. Delivery can be arranged by international express, air cargo or sea freight, with tracking details supplied after dispatch. Freight-collect shipments and delivery to a customer warehouse or forwarder can also be coordinated.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.