MTP-8 APC to 4 x MDC UPC Harness, 8 Fibers, OS2, Type B

MTP-8 APC to 4 x MDC UPC Harness, 8 Fibers, OS2, Type B

This MTP® Elite Female harness fans one multi-fiber connector out to duplex LC legs, replacing a cassette and patch cords with a single factory tested assembly. OS2 9/125µm fiber, 8 Fibers, Plenum (OFNP) jacket.

Standard lengths are 1m (3ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), 20m (66ft), 25m (82ft), 30m (98ft) and 40m (131ft). Because we are the manufacturer, any other length between or beyond these steps can be produced on request, with your choice of jacket color, labeling and packaging.

Product Highlights

  • MTP® Elite Female (Non-Pinned) to MDC UPC, 8 Fibers
  • OS2 9/125µm, G.657.A1
  • Insertion loss ≤0.35dB (0.15dB Typ.), return loss ≥60dB
  • Type B polarity
  • 3.0mm Plenum (OFNP) round cable
  • Minimum bend radius 10mm
  • Ten standard lengths from 1m (3ft) to 40m (131ft), custom lengths built to order

Specifications

Part Number8FMTPMDCSMF
ManufacturerHT
Connector AUS Conec MTP® Elite Female (Non-Pinned)
Connector BUS Conec MDC UPC
Fiber ModeOS2 9/125µm
Wavelength1310nm
Polish TypeAPC to UPC
PolarityType B
Cable JacketPlenum (OFNP)
Fiber Count8 Fibers
Glass FiberG.657.A1
Minimum Bend Radius10mm
Breakout Outside Diameter (OD)2.0mm
Cable Outside Diameter (OD)3.0mm
Installation Tensile Load66N
Tensile Strength80/240N (Long/Short Term)
MTP Connector IL≤0.35dB (0.15dB Typ.)
MTP Connector RL≥60dB
MDC Connector IL≤0.3dB
MDC Connector RL≥50dB
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-10 to 70°C (14 to 158°F)

Applications

Typical uses include connecting a parallel optics port to multiple duplex LC ports, wiring between an MPO backbone and LC equipped switches or servers, and neat fan-out at the equipment rack. The 8-fiber version matches 400G and 800G parallel interfaces that run on 4 or 8 lanes, such as QSFP112, OSFP and twin-port OSFP connections.

LC Legs and Port Mapping

Every LC duplex leg is factory polished and tested individually, with return loss well above the multimode or single mode requirement. The fan-out is compact and strain relieved, and the leg numbering matches the polarity table for error-free patching.

Ordering Information

To order, quote 8FMTPMDCSMF together with the length and quantity you need. The 1m (3ft) version is the standard model; Private labeling, custom packaging and project specific documentation are all handled in-house.

Quality and Testing

Every MPO/MTP assembly leaving our factory is 100% tested for insertion loss and return loss, with end face geometry checks on the multi-fiber ferrules. Controlled polishing keeps the loss budget stable across the whole batch, which matters when several mated pairs sit in one link.

Built to Your Spec

Our engineering team handles custom MPO/MTP assemblies daily. If the standard configuration does not match your link design, send us the requirement and we will build exactly what your network needs at factory-direct cost.

Logistics

Most orders leave our facility within a few working days. Courier, air freight and sea freight are all available, and we are happy to hand goods to your nominated forwarder in China.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.