High-density designs should assess this item together with panel access, cable routing and the complete optical loss allowance. This custom pigtail platform is built to the ordered arrangement: OS2 fiber mode, connector range, polish, jacket rating and length are all confirmed before manufacturing begins. Every leg is factory terminated, polished and optically tested; consequently, the splice point inherits a connector end face that field polishing cannot match.
| Connector A | LC/SC/FC/ST/LSH UPC/APC Simplex |
|---|---|
| Connector B | Unterminated |
| Fiber Count | 4/6/8/12/24/48/96 Fibers |
| Fiber Grade | G.657.A1 |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Breakout Length | 0.3/0.5m |
| Cable Jacket | 0.9mm: PVC (Unrated)/LSZH |
| Min. Bend Radius (Optical Fiber) | 10mm |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Connector Durability | 1000 Times |
| Attenuation at 1310nm | 0.36dB/km |
| Attenuation at 1550nm | 0.22dB/km |
| Insertion Loss | ≤0.3dB |
| Return Loss | UPC≥50dB, APC≥60dB (LC/SC/ST/FC) |
| Operating Temperature | Plenum (OFNP): -10 to 60°C (14 to 140°F) |
| Storage Temperature | Plenum (OFNP): -10 to 70°C (14 to 158°F) |
Every structured cabling plant ends the corresponding way: a cable arrives at a frame, and its fibers must become ports. The pigtail is the component that makes that conversion. Spliced into a tray and presented on a panel, each strand gains a connector with a known optical signature, a slot in the documentation and a place in the test record. That conversion - cable to port - is where channel quality is won or lost.
Where a fusion splicer must not be treated as obtainable, mechanical splices get the channel up: the strand cleaves, seats in the mechanical splice body and locks against the field fiber. The loss is higher than a fusion joint and the reflectance worse; consequently, the practice is a fallback rather than a standard - but for urgent restoration work a pigtail that supports both methods keeps the version open.
The custom platform turns a catalog of options into one ordered arrangement: connector range from LC, SC, FC, ST and LSH; polish as UPC or APC; jacket rating to suit the pathway; length to the measured run; and fiber count where the platform offers it. State the combination with the enquiry and the factory confirms the manufacturable specification before manufacturing begins. The delivered pigtail then matches the patch panel hardware, the tray geometry and the pathway without field improvisation.
Three choices decide how a custom pigtail behaves at the splice point: this connector interface range must correspond to the patch panel adapters, the polish discipline must correspond to the plant - mixing UPC and APC at one mating point destroys return loss - and the jacket rating must satisfy the pathway code. Getting these right at order time is faster than any field correction, and the factory test report then applies to the specific delivered arrangement.
Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the channel margin intact after the tenth tray opening, not just at commissioning.
Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame slot, keep spare strands capped and bagged, and record which set went into which tray so replacement stock may also be ordered to the identical specification.
Productive termination crews work to a fixed routine: mount the tray, dress this optical cable, splice the pigtails color by color, protect each joint, test each completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame slot in a predictable time, and the test record maps cleanly onto the documentation. The consistency additionally makes quality auditable - corresponding materials, corresponding sequence, corresponding pass criteria across every site.
Five decisions define the order: this connector interface range must correspond to the patch panel, the polish must correspond to the plant, the fiber mode must correspond to this optical cable, the structure must correspond to the pathway, and the count must correspond to the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the requirement sits outside the standard configurations, the custom platforms cover the remaining combinations.
Every pigtail is optically tested before packing: insertion loss and return loss are verified on each terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results obtainable on ask for.
Refer to this pigtail by connector, polish, fiber mode, fiber count and structure during the request for a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packaging - send the requirement with the enquiry and the factory will review the manufacturable specification. Project orders can be reviewed for interface compatibility, packing details and delivery coordination.
Please write to sales@huihongfiber.com, we will reply as soon as possible.
| Fiber Optic Test Equipment |
| Fiber Optic Tool Kits |
Huihong TechnologiesAdd:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,ChinaEmail:info@huihongfiber.com Tel: 86.755.61230063 Specialized fiber optic products manufacturer. |
Fiber Optic Quick Guide |
News and ExhibitionsCompany news and exhibitions schedules for this year and next year. click here for details . |
Fiber Optic Applications
|
Customer Support
|