Network installers should begin with the actual mating interfaces and site fiber records before assigning this product to a link. This project-specific multi-fiber cable is a pre-terminated indoor/outdoor rated product built exactly to the arrangement the project specifies: connector styles and polish at each end, fiber count, jacket rating, breakout geometry and length are all specified at order time, and the finished trunk is optically tested leg by leg before dispatch. Because the indoor/outdoor structure carries a flame-rated jacket that further tolerates moisture and ultraviolet exposure, one product can run from an outdoor entry point directly into the building without a transition splice at the wall.
| Connector Type | LC/SC/ST/FC/Unterminated |
|---|---|
| Polish Type | UPC |
| Fiber Mode | OM2 50/125μm |
| Fiber Count | 4 Fibers |
| Minimum Bend Radius | 20/10D (Dynamic/Static) |
| Breakout Outside Diameter (OD) | 2.0mm |
| Trunk Outside Diameter (OD) | 5.0mm |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥30dB |
| Cable Type | Tight Buffered |
| Fiber Grade | Bend Insensitive |
| Operating Temperature | -20 to 60°C (-4 to 140°F) |
When a legacy trunk fails, the appropriate repair is a cable that matches the deployed fiber grade. Because mixing OM1 with OM3 introduces a core-size transition that adds unpredictable loss, building the replacement trunk on the original grade is cheaper than diagnostics a mismatched one.
OM1 and OM2 cabling remains in service in industrial controls, building automation and older campus networks. This cable assembly matches that plant: the 62.5/125 or 50/125 core mates correctly with the current infrastructure, avoiding the modal mismatch that mixing core sizes would create.
A pre-terminated trunk is only as good as its journey through the pathway. The optional pulling eye protects the connectorized end during the pull and keeps the trunk cable from twisting, which matters on long riser runs and congested trays. The installation load rating on the datasheet is the number the pulling rope should respect, not the weight of the reel.
The breakout is where a trunk becomes usable. Equal-length legs suit a straight row of adjacent ports, whereas staggered legs reach a column of ports without slack piling up at one end. The 2.0mm legs survive patching-field handling; the 0.9mm model suits protected routing inside panels and cassettes. Specifying the geometry at order time means the cable assembly arrives matching the hardware it serves.
A multi-fiber trunk is planned once and deployed once; therefore, the planning deserves the hour it takes. Measure the pathway through the actual containment, note the bend space at both connector ends, and decide which end gets pulled. State the pulling eye specification with the order if the pathway is long or congested. At the far end, leave the dressing slack the adapter panel or cassette needs - the datasheet breakout lengths are the default, and other geometries are confirmed before manufacturing.
Terminating OM2 fiber in the field means a splicer, a tray slot, consumables and the craft time to do it well - multiplied by every fiber in the trunk cable. A pre-terminated product moves all of that work to the factory floor, where polishing, inspection and testing happen under controlled conditions. The installer who receives the optical cable routes it, dresses the legs and mates the optical connectors; the channel is ready for light the matching hour. Since every field-terminated leg is one more chance for a rework visit, for multi-fiber counts the saving is never linear but compounding,.
Fiber count is specified at order time: 4 Fibers, 8 Fibers are standard options for this structure. Specifying the count is a capacity decision - plan the active links, add the spares the upkeep practice calls for, and the trunk cable arrives with every leg terminated and tested.
Regular lengths cover the common routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft), 30m (98ft), 25m (82ft), with project-specific length obtainable beyond the list, including foot-based builds for projects specified in imperial units. Specifying the measured pathway length keeps the slack out of the tray and the strain off the optical connectors.
Every trunk is terminated with precision zirconia ferrule connectors and optically tested leg by leg before packing: insertion loss and return loss are verified on each fiber, and end-face geometry is inspected for consistent physical contact. The cable assembly ships with dust caps on every connector and the test results obtainable on ask for.
Refer to this arrangement by fiber mode, fiber count, connector pair, breakout geometry and length when asking for a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, pulling eye, marking or project packaging - send the specification with the request and the factory will check the build before manufacturing. Project support is available to reconcile the ordered configuration with the intended installation.
Please write to sales@huihongfiber.com, we will reply as soon as possible.
| Fiber Optic Test Equipment |
| Fiber Optic Tool Kits |
Huihong TechnologiesAdd:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,ChinaEmail:info@huihongfiber.com Tel: 86.755.61230063 Specialized fiber optic products manufacturer. |
Fiber Optic Quick Guide |
News and ExhibitionsCompany news and exhibitions schedules for this year and next year. click here for details . |
Fiber Optic Applications
|
Customer Support
|