For procurement and engineering teams, the specification provides a practical basis for checking compatibility before production is requested. This custom-built multi-fiber cable is a pre-terminated indoor unit built exactly to the setup the project specifies: connector styles and polish at every end, fiber count, jacket rating, breakout geometry and length are all specified at order time, and the finished trunk is optically tested leg by leg before dispatch. Because the tight-buffered breakout build gives each fiber its own 2.0mm or 0.9mm leg, the trunk assembly terminates directly into panels and hardware without a splice tray or fan-out kit.
| Connector Type | LC/SC/ST/FC/LSH/Unterminated |
|---|---|
| Polish Type | UPC to UPC |
| Fiber Mode | OM4 50/125μm |
| Wavelength | 850/1300nm |
| Fiber Count | 4 Fibers |
| Cable Jacket | Riser (OFNR)/LSZH/Plenum (OFNP) |
| Fiber Grade | Bend Insensitive |
| Minimum Bend Radius | 20/10D (Dynamic/Static) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥20dB |
| Attenuation at 850nm | 3.0dB/km |
| Attenuation at 1300nm | 1.0dB/km |
| Breakout Outside Diameter (OD) | 2.0/0.9mm |
| Trunk Outside Diameter (OD) | 7.5±0.5/4.8±0.3mm |
| Breakout Type | 0.3/0.5m Equal Breakout (Default) |
| Polarity (Duplex) | A (Tx) to B (Rx) |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | Riser (OFNR)/Plenum (OFNP): -20 to 70°C (-4 to 158°F) |
OM4 raises the effective modal bandwidth to 4700 MHz-km at 850nm, and that headroom translates directly into reach for the higher-speed interfaces. Because the price difference against OM3 has largely disappeared, new cabling plants standardize on OM4 and keep OM3 only for matching present installations.
A multi-fiber trunk changes how a row is provisioned: instead of pulling twelve duplex patch cords, one unit carries twelve fibers and fans out at every end. The pathway fills less, this adapter panel field stays readable, and adding a connection later means using a spare leg rather than pulling a new cable.
The breakout is where a trunk becomes usable. Equal-length legs suit a straight row of adjacent ports, whereas staggered legs reach a column of ports without slack piling up at one end. The 2.0mm legs survive patching-field handling; the 0.9mm version suits protected routing inside panels and cassettes. Selecting the geometry at order time means the terminated assembly arrives matching the hardware it serves.
A pre-terminated trunk is only as good as its journey through the pathway. The optional pulling eye protects the connectorized end during the pull and keeps the trunk assembly from twisting, which matters on long riser runs and congested trays. The installation load rating on the datasheet is the number the pulling rope ought to respect, not the weight of the reel.
A multi-fiber trunk is planned once and current once, and therefore the planning deserves the hour it takes. Measure the path through the actual containment, note the bend space at the two interfaces, and decide which end gets pulled. State the pulling eye specification with the order if the path is long or congested. At the far end, leave the dressing slack this adapter panel or cassette needs - the datasheet breakout lengths are the default, and other geometries are confirmed before factory assembly.
Terminating OM4 fiber in the field means a splicer, a tray location, consumables and the craft time to do it well - multiplied by each fiber in the trunk assembly. A pre-terminated unit moves all of that work to the factory floor, where polishing, inspection and testing happen under controlled conditions. The installer who receives the installed cable routes it, dresses the legs and mates the optical interfaces; the connection is ready for light the identical hour. Since each field-terminated leg is a different chance for a rework visit, for multi-fiber counts the saving is not to be considered linear but compounding,.
Fiber count is specified at order time: 4 Fibers, 6 Fibers, 8 Fibers, 12 Fibers, 16 Fibers, 24 Fibers, 48 Fibers are standard options for this build. Selecting the count is a capacity decision - plan the active links, add the spares the servicing practice calls for, and the trunk assembly arrives with each leg terminated and tested.
Catalogue lengths cover the common routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft), 30m (98ft), with custom-built length offered beyond the list, including foot-based builds for projects specified in imperial units. Specifying the measured path length keeps the slack out of the tray and the strain off the optical interfaces.
Each trunk is terminated with precision zirconia ferrule connectors and optically tested leg by leg before packing: insertion loss and return loss are verified on every fiber, and end-face geometry is inspected for consistent physical contact. The terminated assembly ships with dust caps on every installed connector and the test results offered on specify.
Refer to this setup by fiber mode, fiber count, connector pair, breakout geometry and length when specifying a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, pulling eye, identification or project packing - send the specification with the request and the factory will make certain of the build before factory assembly. A clear port or maintenance schedule helps us confirm the correct factory-built configuration before supply.
Please write to sales@huihongfiber.com, we will reply as soon as possible.
| Fiber Optic Test Equipment |
| Fiber Optic Tool Kits |
Huihong TechnologiesAdd:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,ChinaEmail:info@huihongfiber.com Tel: 86.755.61230063 Specialized fiber optic products manufacturer. |
Fiber Optic Quick Guide |
News and ExhibitionsCompany news and exhibitions schedules for this year and next year. click here for details . |
Fiber Optic Applications
|
Customer Support
|