Skip to content
You are here:

Customized Simplex OM4 LC/SC/FC/ST/LSH Fiber Optic Pigtail

Customized Simplex OM4 LC/SC/FC/ST/LSH Fiber Optic Pigtail

This product is best evaluated as part of the complete network path, including its connectors, mapping and acceptance values. This made-to-order pigtail platform is built to the ordered configuration: OM4 fiber mode, connector family, polish, jacket rating and length are all confirmed before the build starts. Each leg is factory terminated, polished and optically tested, which means the splice point inherits a connector end face that field polishing cannot match.

Product Highlights

  • Easy-strip Tight-buffered Coating
  • Available in PVC (Unrated)/Riser (OFNR)/LSZH/Plenum (OFNP) Cable Jacket
  • Available in LC, SC, FC, ST, LSH Connectors
  • Optical Testing Guarantees Insertion Loss and Returns Loss
  • Pass All IEC-61754 and TIA-604 (FOCIS) Performance Requirements

Specifications

Connector ALC/SC/FC/ST/LSH UPC Simplex
Connector BUnterminated
Fiber Count1 Fiber
Fiber GradeBend Insensitive
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Jacket ColorAqua
Cable Jacket0.9mm: PVC (Unrated)/LSZH
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Connector Durability1000 Times
Attenuation at 850nm3.0dB/km
Attenuation at 1300nm1.0dB/km
Insertion Loss≤0.3dB
Return Loss≥20dB
Operating TemperaturePlenum (OFNP): -10 to 60°C (14 to 140°F)
Storage TemperaturePlenum (OFNP): -10 to 70°C (14 to 158°F)

Why pigtails remain the standard termination

A pigtail is half a connection: one end is an assembled at the factory connector, polished and tested under process control; the other is a bare fiber strand ready for the splice. Fusion-splicing that strand onto the fitted cable brings the interface connector quality of the factory to a field route. The result outperforms field-polished connectors on insertion loss, return loss and long-term stability, and it outperforms pre-terminated trunks when the route length is uncertain or the pathway is difficult to pre-measure.

Fusion splicing practice that protects the budget

A good splice starts long before the splicer arcs: strip the strand cleanly, cleave square, keep the sleeve staged, and protect the completed splice in the tray with the bend radius respected. The tight-buffered 0.9mm coating on this pigtail strips in one motion and seats cleanly in standard splice sleeves. Done well, a fusion splice adds less attenuation than a connector pair and stays stable for the life of the plant. Retaining this detail with the acceptance records supports consistent maintenance.

Ordering a customized pigtail platform

The made-to-order platform turns a catalog of options into one ordered configuration: connector family from LC, SC, FC, ST and LSH; polish as UPC or APC; jacket rating to suit the route; length to the measured run; and fiber count where the platform offers it. State the combination with the enquiry and the factory confirms the manufacturable specification before the build starts. The delivered pigtail then matches the rack panel hardware, the tray geometry and the route without field improvisation.

Configuration choices that matter at the tray

Three choices decide how a made-to-order pigtail behaves at the splice point: the interface connector family must correspond to the rack panel adapters, the polish discipline must correspond to the plant - mixing UPC and APC at one mating point destroys return loss - and the jacket rating must satisfy the pathway code. Getting these right at order time is faster than any field correction, and the factory test report then applies to the exact delivered configuration.

Choosing the fiber mode for the plant

Single-mode OS2 serves long links, PON access and any plant where distance or wavelength plans matter; the bend-insensitive glass grade keeps attenuation stable in dense trays. OM3 and OM4 multimode serve hardware rooms and data halls where transceiver cost favors short-reach optics. OM1 and OM2 remain in service in legacy plants and must be matched like-for-like. The pigtail mode must equal the cable assembly plant mode - a mismatch splices poorly and performs worse.

Bend-insensitive glass in dense trays

Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the link margin intact after the tenth tray opening, not just at commissioning. Retaining this detail with the acceptance records supports consistent maintenance.

A splicing workflow that scales

Productive termination crews work to a fixed routine: mount the tray, dress the cable assembly, splice the pigtails color by color, protect every joint, test every completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame position in a predictable time, and the test record maps cleanly onto the documentation. The consistency also makes quality auditable - same materials, same sequence, same pass criteria across each site.

Sparing and kit planning for termination work

Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame position, keep spare strands capped and bagged, and record which set went into which tray so replacement stock can readily be ordered to the identical specification.

Selecting the right pigtail for the job

Five decisions define the order: the interface connector family must correspond to the rack panel, the polish must correspond to the plant, the fiber mode must correspond to the cable assembly, the construction must correspond to the route, and the count must correspond to the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the requirement sits outside the standard configurations, the made-to-order platforms cover the remaining combinations.

Quality Control and Testing

Each pigtail is optically tested before packing: insertion loss and return loss are verified on every terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results available on request.

Ordering and Factory Support

Refer to this pigtail by connector, polish, fiber mode, fiber count and construction at the request stage a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packing - send the requirement with the enquiry and the factory will establish the manufacturable specification. For orders, our team can check the requirement before coordinating manufacture and international delivery.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.