For project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. FC/APC Single Mode Fixed Fiber Optic Attenuator inserts a precisely calibrated fixed loss into a fiber connection. The attenuating element is ion-doped fiber - the loss is spectrally flat and reflection-free, unlike air-gap or offset designs - so the connection sees exactly the rated attenuation at each operating wavelength. The male-to-female plug body attaches directly to this panel adapter or transceiver port, adding attenuation without an extra patch cord in the route.
| Fiber Connector | FC/APC |
|---|---|
| Polish Type | APC |
| Connector Gender | Fixed Male to Female |
| Attenuation | 1~25dB |
| Operating Wavelength(nm) | 1260~1620 |
| Operating Temperature Range | -25 to 70°C (-13 to 158°F) |
| Storage Temperature Range | -40 to 85°C (-40 to 185°F) |
| Application(1) | Matching Product(1) |
| Return Loss | ≥60dB (APC) |
The FC/APC fixed attenuator is available across the full standard range: 1dB, 2dB, 3dB, 4dB, 5dB, 6dB, 7dB, 8dB, 9dB, 10dB, 11dB, 12dB, 13dB, 14dB, 15dB, 16dB, 17dB, 18dB, 19dB, 20dB, 21dB, 22dB, 23dB, 24dB, 25dB. Every value is individually calibrated at 1310 nm and 1550 nm and the rated figure is marked on each housing, so the ordered value is exactly the installed value. State the required figure - for example FC/APC 10dB - with the enquiry.
1dB 2dB 3dB 4dB 5dB 6dB 7dB 8dB 9dB 10dB 11dB 12dB 13dB 14dB 15dB 16dB 17dB 18dB 19dB 20dB 21dB 22dB 23dB 24dB 25dB
Optical links are engineered with a power budget: the transmitter launches, the fiber and connectors consume, and the receiver expects what remains inside a defined window. Short routes, dense wavelength plans and high-power transmitters may all deliver too much light, and an overloaded receiver distorts exactly like an overloaded amplifier - errors appear on a connection that tests perfectly on loss alone. A fixed attenuator brings the received power back inside the window, and the connection behaves as designed.
The cleanest way to attenuate light is to absorb it inside the fiber itself. Ion-doped fiber attenuators do exactly that: a short section of doped glass absorbs a calibrated fraction of the optical power and converts it to negligible heat. Because the attenuation happens inside the core, the light that emerges keeps its mode profile and the device adds virtually no reflectance. The alternatives - air gaps, offsets and misaligned ferrules - all trade loss against reflections and modal noise, which is why precision attenuators abandoned them. Record this requirement with the project documents so the supplied configuration can be checked on arrival.
The right figure is the difference between what the connection delivers and what the receiver wants, plus a small margin. Measure or calculate the expected receive power first; then choose the nearest standard figure - 1, 2, 3, 5, 7, 10, 15, 20 or 25 dB - that lands the receiver inside its window. Too little attenuation leaves the receiver overloaded; too much eats the margin that aging and repairs will need later. When the need sits between standard figures, the custom platform covers the precise figure.
Fixed attenuators win on stability, size and price: once the necessary loss is known, a fixed device holds it permanently with no moving parts. Variable attenuators win when the loss itself is the question - receiver sensitivity testing, margin surveys, multi-wavelength leveling - where sweeping the figure is the whole point. Most plants need the two: fixed units existing in the links, and a variable instrument in the test kit.
The plug-style body turns the attenuator into a connector accessory rather than a cable unit: the male end seats directly in this panel adapter or the transceiver port, and the installed patch cord mates to the female end. No extra jumper, no extra mating pair, no extra loss beyond the rated figure. In dense frames this matters twice - once in the optical loss budget, and once in this cable management behind this panel.
An attenuator sits in the middle of the connection, so its reflectance counts twice - once toward the transmitter and once toward the receiver. UPC versions hold return loss at 50 dB or better, and APC versions at 60 dB or better, which keeps reflected power far below anything a modern transmitter notices. The polish grade must be matched to the plant: an APC attenuator mated to a UPC connector through an adapter damages the two end faces and destroys the very return loss it was selected to protect.
An attenuator is a connector with optics inside, and connector rules apply: keep the caps on until the moment of mating, clean each end face before insertion, and never mate a contaminated ferrule into the device - the dirt transfers to the attenuator end face and the next connector that touches it. Store spare units capped and bagged, and record which connection every existing unit serves so replacement orders match the original figure.
Four decisions define the order: the attenuation figure must be matched to the connection calculation, this connector series must be matched to the port or the patch cords, the polish grade must be matched to the plant, and the body style - plug or inline - must suit the deployment. Fixed figures cover permanent installations; the variable instruments cover testing; the test cable covers transceiver qualification. Getting all four right at order time is what turns a small component into a dependable part of the connection.
Each attenuator is optically verified before packing: the attenuation figure is measured at the operating wavelengths and checked against its rated tolerance, return loss is verified to its polish grade, and this connector end faces are inspected for scratches and contamination. Units ship capped and bagged.
Refer to this attenuator by attenuation figure, connector series, polish grade and body style when ordering a quotation. For figures or configurations outside the listed options - non-standard dB figures, mixed connector pairings or project packing - send the need with the inquiry and the factory will verify the manufacturable specification. Our project support can review the requirement with Shenzhen production before a formal quotation is issued.
Please write to sales@huihongfiber.com, we will reply as soon as possible.
| Fiber Optic Test Equipment |
| Fiber Optic Tool Kits |
Huihong TechnologiesAdd:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,ChinaEmail:info@huihongfiber.com Tel: 86.755.61230063 Specialized fiber optic products manufacturer. |
Fiber Optic Quick Guide |
News and ExhibitionsCompany news and exhibitions schedules for this year and next year. click here for details . |
Fiber Optic Applications
|
Customer Support
|