Juniper Networks JNP-100G-4X25G-2.5M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 2.5m (8ft)

Juniper Networks JNP-100G-4X25G-2.5M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 2.5m (8ft)

This HT cable matches the JNP-100G-4X25G-2.5M requirement for Juniper Networks equipment. The 2.5m (8ft) assembly supports 100G operation and provides a factory-terminated passive copper link without separate optical modules or patch cords; its complete electrical and mechanical details are listed below.

OEM Part Number: JNP-100G-4X25G-2.5MHT Part Number: JNP-100G-4X25G-2.5M

Product Highlights

  • Compatible alternative to Juniper Networks JNP-100G-4X25G-2.5M
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to SFP28
  • Fixed length and part number: 2.5m (8ft), JNP-100G-4X25G-2.5M
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.125W
  • Minimum bend radius: 60mm

Specifications

HT Part NumberJNP-100G-4X25G-2.5M
Juniper Networks CompatibleJNP-100G-4X25G-2.5M
ManufacturerHT
Form FactorQSFP28 to SFP28
Max Data Rate100Gbps
Cable TypePassive Twinax
Cable Length2.5m (8ft)
Wire AWG30AWG
Minimum Bend Radius60mm
Power Consumption≤0.125W
Power Supply3.3V
MTBF=50 Million Hours
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
MediaCopper
Application100G to 4x 25G Ethernet, Data Centers
ProtocolsIEEE 802.3, QSFP28 MSA, SFF-8665

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that JNP-100G-4X25G-2.5M reaches both ports without tension at either connector.

Position Within the Length Range

JNP-100G-4X25G-2.5M occupies the middle of this family between JNP-100G-4X25G-2M at 2m (7ft) and JNP-100G-4X25G-3M at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Juniper Networks Compatibility and Factory Testing

The assembly is configured for equipment that recognizes JNP-100G-4X25G-2.5M. Before shipment, we inspect both connectors and verify identification, link establishment and electrical continuity, link stability and diagnostic readouts. Host hardware and firmware revisions can affect third-party cable acceptance, so customers can provide the equipment model and software release for a pre-order compatibility review.

Ordering Information

This product is ordered as JNP-100G-4X25G-2.5M in 2.5m (8ft). Include the equipment model and software release if you would like a pre-order compatibility review. Other lengths use different part numbers and should not be substituted into the same order line.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks JNP-100G-4X25G-2.5M.

What information should I provide for a compatibility check?

Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.

Does this page include more than one cable length?

No. This page is dedicated to 2.5m (8ft) and part number JNP-100G-4X25G-2.5M. Other lengths have their own part numbers and product pages.

Are separate optical modules required?

No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.

Quality Assurance and Packaging

Before packing, our team checks the cable jacket, connector boots, latches and identification of each assembly. The cable is then secured in a loose coil and protected against dust and connector impact. Neutral packaging, customer part-number labels and project-specific carton lists can be supplied on request.

Shipping and Lead Time

Stock items are generally dispatched within one to three working days after order confirmation. DHL, UPS, FedEx, TNT and EMS are available for international delivery; larger consolidated orders can move by air or sea freight. Customer courier accounts and nominated forwarders are accepted.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.