LC UPC Duplex OS2 Fiber Keystone Jack

LC UPC Duplex OS2 Fiber Keystone Jack

Keeping the configuration, branch identification and installation requirement consistent across every participating site pays off at acceptance time. %s brings fiber to the work-space outlet in the equivalent keystone format used for copper jacks. This coupler snaps into standard keystone faceplates, surface boxes and patch panels; as a result, the fiber drop terminates exactly where the user needs it - at the desk, the cabinet or the consolidation point.

Product Highlights

  • High-precision Mating Structure with ≤0.2dB (Typical) Low Insertion Loss
  • Sturdy Snap-in Construction for Fast and Tool-less Installation
  • Color-coded for Rapid Fiber Management
  • Used for Keystone Wall Plates or Panels with Standard-sized Keystone Openings
  • One-piece Dust Cap Keeps Adapter’s Interior Clean from Dust

Specifications

Connector TypeLC-LC
Body StyleDuplex
Polish TypeUPC
Fiber ModeSingle Mode
Insertion Loss≤0.2dB
Durability1000 times
Mounting TypeReduced Flanged
ColorBlue
Flammability RateUL 94V-0
RoHS Compliancy StatusCompliant
Operating Temperature Range-25 to 70℃ (-13 to 158℉)
Storage Temperature Range-25 to 70℃ (-13 to 158℉)
Structure(1)Q:

Phosphor bronze and zirconia sleeves compared

Two sleeve materials dominate this coupler market. Zirconia ceramic sleeves give the tightest alignment and are the right alternative for single-mode and high-operation multimode work, where core geometry leaves no room for eccentricity. Phosphor bronze sleeves serve legacy multimode and metallic-ferrule connectors where the tolerance need is looser and the cost matters more. Matching the sleeve to the application keeps both operation and budget under control.

Fiber at the work-area outlet

The keystone format standardized copper work-space outlets decades ago, and fiber keystone jacks put optical ports in the equivalent faceplates, surface boxes and floor outlets. The jack snaps in from the front, the pigtail or cord terminates behind, and the user sees a clean shuttered port. For fiber-to-the-desk, industrial terminals and consolidation points, the keystone jack turns a fiber drop into an outlet that matches every other outlet on the wall.

Faceplates, boxes and keystone panels

A keystone jack is only as useful as the hardware that holds it. Standard faceplates take one to four jacks; surface-mount boxes serve retrofits where the wall cannot be opened; keystone patch panels load twenty-four jacks into a rack unit for space-efficient termination. Mixing fiber jacks with copper jacks in one faceplate is normal practice - the format is shared; as a result, the outlet plan follows the services, not the other way around.

Shuttered adapters in live environments

An open adapter port is an invitation to dust, and dust on a ferrule end face is the single most common cause of unexplained loss. A shuttered adapter closes an internal flap the moment the connector interface withdraws, keeping the sleeve bore clean until the next mating. The equivalent shutter blocks the direct line of sight into a live port, a small but real safety gain where high-power transmitters are in service. Shuttered versions cost slightly more and repay it the first time a port stays clean through a long design phase.

What adapter testing actually measures

An adapter contributes no signal of its own; as a result, its test is a mating test: reference connectors mate through this coupler, and the inserted loss is recorded. A zirconia-sleeve adapter should add no more than 0.2 dB, and the mating must repeat that figure across cycles. Durability testing runs the mating hundreds of times and re-measures - a sleeve that wears loose announces itself as creeping loss. These figures, not the housing color, are what separates an adapter that serves for years from one that becomes the mystery fault.

Selecting the right adapter for the panel

Five decisions define this coupler order: the connector interface pairing must align with both sides of the mating, the mounting style must fit the fiber panel cutout, the polish color code must align with the plant, the sleeve material must suit the operation grade, and the count must cover the load-out plus spares. Getting all five right at order time is what turns a bag of couplers into a dependable panel. Where the pairing crosses connector families, the hybrid range covers the common conversions.

Quality Control and Testing

Every adapter is inspected before packing: the sleeve bore is checked for alignment and surface finish, the housing latches are cycled for positive engagement, and sample matings from each production lot are measured for insertion loss. Accessories are checked for fit against the adapters they serve. Project teams can carry this requirement into the site documentation used by each contractor.

Ordering and Factory Support

Refer to this adapter by connector pairing, mounting style, polish grade and pack unit count when submitting a request for a quotation. For configurations outside the listed options - mixed packs, panel hardware kits or project packaging - send the need with the inquiry and the factory will validate the manufacturable specification. Customers can include multi-site labeling or documentation requirements when requesting a project quotation.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.