Skip to content
You are here:

LC UPC Quad OS2 SC Footprint Fiber Adapter with Flange

LC UPC Quad OS2 SC Footprint Fiber Adapter with Flange

Engineering teams can use the documented values below to compare the product with the intended channel and as-built requirements. LC UPC Quad OS2 SC Footprint Fiber Adapter with Flange couples two LC/UPC connectors into one continuous optical optical route. Inside the housing, a zirconia ceramic sleeve holds the two ferrules on a common axis, keeping insertion loss low and consistent across hundreds of mating cycles. The flanged housing screws directly to the relevant panel cutout for a permanent, vibration-proof mounting.

Product Highlights

  • ≤0.2dB(Typical) Low Insertion Loss
  • Color Coded for Rapid Fiber Management
  • 2x Duplex Dust Cap Keeps Adapter’s Interior Clean from Dust
  • Stainless Steel Clips for Tool-less Snap-in Installation
  • Available in A Variety of Connector Types

Specifications

Connector TypeLC-LC
Body StyleQuad
Polish TypeUPC
Fiber ModeOS2 9/125μm
Insertion Loss≤0.2dB
Durability1000 times
Mounting TypeFull Flanged
ColorBlue
Flammability RateUL 94V-0
RoHS Compliancy StatusCompliant
Operating Temperature-40 to 85℃(-40 to 185℉)
Storage Temperature-10 to 60℃(14 to 140℉)
Connector TypeLC/UPC
Body StyleQuad
Fiber ModeSM OS2
Insertion Loss≤0.2dB

Why the alignment sleeve decides adapter quality

Each optical adapter is, at heart, a sleeve alignment problem: two connector ferrules must meet on one axis with their end faces touching, and any eccentricity shows up directly as insertion loss. Zirconia ceramic is the standard sleeve material given that it machines to sub-micron tolerance, resists wear across repeated matings and holds its dimensions through temperature swings. The adapters in this range use zirconia sleeves rated for insertion loss of 0.2 dB or better, which keeps an adapter pair well inside any loss-budget calculation.

Flanged and flangeless mounting compared

A flanged adapter fastens to the relevant panel with two screws through the mounting ears: the joint is rigid, resists vibration and stays put for years, which suits frames and enclosures that move or ship. A flangeless adapter snaps into the cutout on spring latches: item is faster, density is higher, and a failed adapter swaps out in seconds without tools. Most panel families accept one style or the other; therefore, the alternative follows the relevant panel hardware already in the plant.

UPC and APC discipline at the adapter

The relevant adapter has no polish of its own, but it is where polish discipline succeeds or fails: mating a UPC connector to an APC connector through any adapter damages the two end faces and wrecks return loss. Color coding exists to prevent exactly that - green housings for APC, blue for UPC single-mode - and the discipline only works when the whole plant follows it. Keep the relevant adapter color, the relevant connector boot color and the documentation consistent, and the mixing mistake becomes nearly impossible.

What adapter testing actually measures

Because an adapter contributes no signal of its own, its test is a mating test: reference connectors mate through the relevant adapter, and the inserted loss is recorded. A zirconia-sleeve adapter ought to add no more than 0.2 dB, and the mating must repeat that figure across cycles. Durability testing runs the mating hundreds of times and re-measures - a sleeve that wears loose announces itself as creeping loss. These figures, not the housing color, are what separates an adapter that serves for years from one that becomes the mystery fault.

Selecting the right adapter for the panel

Five decisions define the relevant adapter order: the relevant connector pairing must be compatible with the two sides of the mating, the mounting style must fit the relevant panel cutout, the polish color code must be compatible with the plant, the sleeve material must suit the behavior grade, and the count must cover the load-out plus spares. Getting all five right at order time is what turns a bag of couplers into a dependable panel. Where the pairing crosses connector families, the hybrid range covers the common conversions.

Quality Control and Testing

Each adapter is inspected before packing: the sleeve bore is checked for alignment and surface finish, the housing latches are cycled for positive engagement, and sample matings from every production lot are measured for insertion loss. Accessories are checked for fit against the adapters they serve.

Ordering and Factory Support

Refer to this adapter by connector pairing, mounting style, polish grade and pack quantity when requisitioning a quotation. For configurations outside the listed options - mixed packs, panel hardware kits or project packing - send the requirement with the enquiry and the factory will cross-check the manufacturable specification. Project orders can include documentation and labeling requirements alongside the technical configuration.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.