For procurement and engineering teams, the specification provides a practical basis for checking compatibility before production is requested. This OM4 fiber patch cable carries a LC UPC interface on one end and a LC UPC interface on the other, factory terminated on OM4 glass and optically tested as an entire unit. The uniboot build places the two fibers of the duplex connection inside a single round 2.0mm cord with one combined connector housing, halving the installed cable count in dense panels and simplifying polarity management.
| Fiber Count | 2 Fibers |
|---|---|
| Fiber Grade | Bend Insensitive Fiber |
| Fiber Mode | OM4 50/125μm |
| Wavelength | 850/1300nm |
| Flame Rating | Riser (OFNR) |
| Cable Outside Diameter (OD) | 2.0mm |
| Polarity | A (Tx) to B (Rx) |
| Tensile Strength | 60/100N (Long/Short Term) |
| Min. Bend Radius (Optical Fiber) | 7.5mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Insertion Loss | ≤0.2dB |
| Return Loss | ≥30dB |
| Attenuation at 850nm | ≤3.5dB/km |
| Attenuation at 1300nm | ≤1.5dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70℃ (-4 to 158℉) |
| Fiber Grade | B |
A duplex jumper is two fibers with a defined A-to-B crossover. Getting polarity right at the cord level keeps the link consistent end to end, which is why these assemblies are built and tested as a pair rather than as two individual strands.
This OM4 unit serves the short-reach fabric of the data center: 10G and 25G server uplinks, 40G and 100G SR4 spine links and the inter-row runs between them. On OM4 glass, 10G Ethernet holds to 400 meters and 100G SR4 to 100 meters, which covers the overwhelming majority of in-hall routes with margin to spare.
The uniboot design merges the duplex pair into a single round cord and a single connector housing. In a 400G row where each QSFP-DD port consumes a duplex connection, halving the cord count visibly changes the airflow and the manageability of the patching field.
Catalogue lengths cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 8m (26ft), 10m (33ft), with custom-built length offered beyond the list. Specifying the measured path length keeps the slack out of the manager and the strain off the optical interfaces.
Every manufactured assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on every cable, and end-face geometry is inspected for consistent physical contact. The installed cable ships with dust caps on the two connectors and the test result offered on specify.
Refer to this setup by connector pair, fiber mode and length when specifying a quotation. For configurations outside the listed options, mixed connector families, jackets, identification or project packing, send the specification with the request and the factory will make certain of the build before factory assembly. A clear port or maintenance schedule helps us confirm the correct factory-built configuration before supply.
Please write to sales@huihongfiber.com, we will reply as soon as possible.
| Fiber Optic Test Equipment |
| Fiber Optic Tool Kits |
Huihong TechnologiesAdd:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,ChinaEmail:info@huihongfiber.com Tel: 86.755.61230063 Specialized fiber optic products manufacturer. |
Fiber Optic Quick Guide |
News and ExhibitionsCompany news and exhibitions schedules for this year and next year. click here for details . |
Fiber Optic Applications
|
Customer Support
|