LC UPC to LC UPC Duplex Flat Clip Uniboot OS2, 2.0mm, ofnr Fiber Patch Cable

LC UPC to LC UPC Duplex Flat Clip Uniboot OS2, 2.0mm, ofnr Fiber Patch Cable

High-density designs should assess this item together with panel access, cable routing and the complete optical loss allowance. This OS2 fiber patch cable carries a LC UPC interface on one end and a LC UPC interface on the other, factory terminated on OS2 glass and optically tested as a full product. The uniboot structure places both fibers of the duplex channel inside a single round 2.0mm cord with one combined connector housing, halving this optical cable count in high-density panels and simplifying polarity management.

Product Highlights

  • Uniboot Allows One Cable to Carry Two Fibers to Reduce Cable Congestion in High-Density Patch Fields
  • G.657.A1 Bend Insensitive Fiber with 10mm Min. Bend Radius
  • Flat Clip Design Provides Additional Space Between Connectors and Improves Airflow
  • Reverse Polarity without Exposing the Fibers or Needing Any Tools
  • Termination Is Tested to Ensure Network Performance

Specifications

Fiber Count2 Fibers
Fiber GradeG.657.A1 (Compatible with G.652.D)
Fiber ModeOS2 9/125μm
Wavelength1310/1550nm
Flame RatingRiser (OFNR)
Cable Outside Diameter (OD)2.0mm
PolarityA (Tx) to B (Rx)
Tensile Strength60/100N (Long/Short Term)
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Insertion Loss≤0.2dB
Return Loss≥50dB
Attenuation at 1310nm≤0.4dB/km
Attenuation at 1550nm≤0.3dB/km
Operating Temperature-10 to 70°C (14 to 158℉)
Storage Temperature-20 to 70℃ (-4 to 158℉)

Connector and polish choices in the single-mode plant

The OS2 interface on this jumper follows the polish discipline of the network it serves. Mixing polishes on a mated pair destroys the return loss and may damage the ferrules; consequently, the patch side must correspond to the patch panel side exactly. When the documentation is unclear, the boot color and this connector interface housing tell the truth: green for APC, blue or beige for UPC.

Bend tolerance in real cabinets

Patch fields are rarely kind to fiber. Leads pathway through tight managers, sharp tray corners and crowded vertical channels. The bend-insensitive glass in this terminated assembly tolerates a 10mm fiber bend radius; consequently, a hurried routing decision during a night upkeep window will not by itself turn into a measurable penalty on the channel.

Polarity without re-terminating

Uniboot connectors expose the polarity through the housing rather than the termination: the latches or clips let the installer swap the fiber positions without opening the cord. A polarity mistake discovered at turn-up becomes a two-minute correction instead of a replacement order. This check should form part of the rack-access and acceptance review.

Length Options

Standard cable lengths cover the common patching routes: 0.5m (1.6ft), 1m (3ft), 1.5m (5ft), 2m (7ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), with custom length obtainable beyond the list. Specifying the measured pathway length keeps the slack out of the manager and the strain off these optical interfaces.

Quality Control and Testing

Each completed assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on each cable, and end-face geometry is inspected for consistent physical contact. This optical cable ships with dust caps on both connectors and the test result obtainable on ask for.

Ordering and Factory Support

Refer to this arrangement by connector pair, fiber mode and length during the request for a quotation. For configurations outside the listed options, mixed connector families, jackets, marking or project packaging, send the requirement with the enquiry and the factory will review the build before manufacturing begins. Project orders can be reviewed for interface compatibility, packing details and delivery coordination.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.