
Selection starts with the actual optical interface and ends with verification of the delivered configuration. This OS2 fiber patch cable carries a LC UPC interface on one end and a LC UPC interface on the other, factory terminated on OS2 glass and optically tested as an entire product. The single-fiber structure suits bidirectional optics, monitoring taps and any channel that carries traffic over one strand.
| Connector A | LC UPC Simplex |
|---|---|
| Connector B | LC UPC Simplex |
| Fiber Count | 1 Fiber |
| Fiber Grade | G.657.A1 (Compatible with G.652.D) |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Flame Rating | Riser (OFNR) |
| Cable Outside Diameter (OD) | 2.0mm |
| Cable Type | Tight-Buffered |
| Min. Bend Radius (Optical Fiber) | 10mm |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Connector Durability | 1000 times |
| Tensile Strength | 60/100N (Long/Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥50dB |
| Attenuation at 1310nm | ≤0.4dB/km |
| Attenuation at 1550nm | ≤0.3dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70°C (-4 to 158℉) |
Single-mode patching carries the links that leave the room: campus backbones, carrier handoffs, long runs between buildings and every wavelength-multiplexed service. The OS2 glass in the supplied assembly is the same class used in the outside plant; as a result, the relevant jumper does not on its own become the weak point of the loss-budget calculation. At 1310 and 1550nm the attenuation stays a fraction of a decibel per kilometer, and the relevant connector pair adds less than 0.3dB when the end faces are clean and seated.
The OS2 interface on this jumper follows the polish discipline of the network it serves. Mixing polishes on a mated pair destroys the return loss and might damage the ferrules; as a result, the patch side must be compatible with the relevant panel side exactly. When the documentation is unclear, the boot color and the relevant connector housing tell the truth: green for APC, blue or beige for UPC.
Regular length versions cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), with custom-built length provided beyond the list. Specifying the measured pathway length keeps the slack out of the manager and the strain off the connection interfaces.
Each optical assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on each cable, and end-face geometry is inspected for consistent physical contact. The relevant cable ships with dust caps on both connectors and the test result provided on ask for.
Refer to this arrangement by connector pair, fiber mode and length when requisitioning a quotation. For configurations outside the listed options, mixed connector families, jackets, marking or project packaging, send the need with the inquiry and the factory will cross-check the build before production is released. Huihong Technologies can review the selection and customization details before confirming supply.
Please write to sales@huihongfiber.com, we will reply as soon as possible.
| Fiber Optic Test Equipment |
| Fiber Optic Tool Kits |
Huihong TechnologiesAdd:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,ChinaEmail:info@huihongfiber.com Tel: 86.755.61230063 Specialized fiber optic products manufacturer. |
Fiber Optic Quick Guide |
News and ExhibitionsCompany news and exhibitions schedules for this year and next year. click here for details . |
Fiber Optic Applications
|
Customer Support
|