MTP-12 UPC Female to Unterminated Fiber Pigtail, 12 Fibers, OM4

MTP-12 UPC Female to Unterminated Fiber Pigtail, 12 Fibers, OM4

High-density designs should assess this item together with panel access, cable routing and the complete optical loss allowance. This fiber pigtail terminates outside-plant or backbone cable into a connectorized panel: MTP-12 UPC Female to Unterminated Fiber Pigtail, OM4 glass, with a factory-polished MTP UPC connector on one end and a prepared fiber strand on the other. Fusion-spliced onto the incoming cable, it turns a raw fiber pathway into a documented, testable port. The MTP interface carries twelve fibers on one connector; consequently, a single splice operation terminates a full parallel-optics trunk slot.

Product Highlights

  • US Conec MTP® Connector with Optimal 0.35dB Low IL
  • Bend Insensitive Fiber with 7.5mm Min. Bend Radius
  • Ribbon Fiber for Mass-fusion Splicing and Multi-fiber Connectorization
  • Used to Ensure Efficient Use of Space and Rapid Network Deployment
  • For Field Installation Using Fusion and Mechanical Splicing

Specifications

Connector AUS Conec MTP® Elite Female (Non-Pinned)
Connector BUnterminated
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Polish TypeUPC
Fiber Count12 Fibers
Cable JacketUnjacketed
Min. Bend Radius7.5mm
Connector Durability500 times
Tensile Strength80/240N (Long/Short Term)
Insertion Loss≤0.35dB (0.15dB Typ.)
Return Loss≥27dB
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-60 to 85°C (-76 to 185℉)
Storage Temperature-60 to 85°C (-76 to 185℉)
Fiber ModeOM4 50/125μm
Wavelength850/1300nm

From raw fiber route to documented port

Every structured cabling plant ends the corresponding way: a cable arrives at a frame, and its fibers must become ports. The pigtail is the component that makes that conversion. Spliced into a tray and presented on a panel, each strand gains a connector with a known optical signature, a slot in the documentation and a place in the test record. That conversion - cable to port - is where channel quality is won or lost.

Mechanical splicing as the field fallback

Where a fusion splicer must not be treated as obtainable, mechanical splices get the channel up: the strand cleaves, seats in the mechanical splice body and locks against the field fiber. The loss is higher than a fusion joint and the reflectance worse; consequently, the practice is a fallback rather than a standard - but for urgent restoration work a pigtail that supports both methods keeps the version open.

Keeping twelve-fiber splices organized

Multi-fiber splicing rewards method: full one color fully - strip, clean, cleave, splice, sleeve - before starting the next, and dress each finished strand into the tray in sequence. The color-coded set makes the pairing unambiguous, and the tray stays readable for the next technician who opens it. A tray that reads in a clear manner is a tray that gets re-entered without new faults.

Color coding as a working discipline

Twelve fibers, twelve colors, one order: the TIA-598 sequence is the only thing standing between a tidy splice tray and a crossed plant. The strands in this set adhere to the standard sequence; consequently, the splicer matches colors between cable and pigtail without guesswork. When the documentation follows the corresponding sequence, a fault on slot seven months from now is found in minutes rather than traced strand by strand.

MTP pigtails for parallel-optics positions

Parallel-optics trunks arrive as multi-fiber cables and must become MTP ports on the patch panel. A twelve-fiber MTP pigtail makes that conversion in one splice operation per trunk tube: the twelve strands splice onto the backbone, and the factory-polished MTP interface presents the full dozen lanes as a single port. Per-lane documentation follows the fiber positions, keeping polarity and map unambiguous for the transceivers that will mate with the patch panel.

Choosing the fiber mode for the plant

Single-mode OS2 serves long links, PON access and any plant where distance or wavelength plans matter; the bend-insensitive glass grade keeps attenuation stable in dense trays. OM3 and OM4 multimode serve equipment rooms and data halls where transceiver cost favors short-reach optics. OM1 and OM2 remain in service in legacy plants and must be matched like-for-like. The pigtail mode must equal this optical cable plant mode - a mismatch splices poorly and performs worse.

Bend-insensitive glass in dense trays

Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the channel margin intact after the tenth tray opening, not just at commissioning.

Sparing and kit planning for termination work

Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame slot, keep spare strands capped and bagged, and record which set went into which tray so replacement stock may also be ordered to the identical specification.

A splicing workflow that scales

Productive termination crews work to a fixed routine: mount the tray, dress this optical cable, splice the pigtails color by color, protect each joint, test each completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame slot in a predictable time, and the test record maps cleanly onto the documentation. The consistency additionally makes quality auditable - corresponding materials, corresponding sequence, corresponding pass criteria across every site.

Quality Control and Testing

Every pigtail is optically tested before packing: insertion loss and return loss are verified on each terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results obtainable on ask for.

Ordering and Factory Support

Refer to this pigtail by connector, polish, fiber mode, fiber count and structure during the request for a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packaging - send the requirement with the enquiry and the factory will review the manufacturable specification. Project orders can be reviewed for interface compatibility, packing details and delivery coordination.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.