This HT cable matches the OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-3M10FT requirement for multi-vendor equipment. The 3m (10ft) assembly supports 800G operation and provides an active electrical link with signal recovery designed for the stated data rate; its complete electrical and mechanical details are listed below.
OEM Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-3M10FTHT Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-3M10FT
| HT Part Number | OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-3M10FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active Breakout DAC (AEC) |
| Cable Length | 3m (10ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 26.5mm |
| Wire AWG | 32AWG |
| Max. Power Consumption | 12W (800G End)10W (400G Per End) |
| Modulation Format | 8x100G-PAM4 to Dual 4x100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G/400G Ethernet |
| Protocols | OSFP MSA Rev5.1, IEEE 802.3ck, CMIS 5.0 |
The listed modulation format is 8x100G-PAM4 to Dual 4x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-3M10FT occupies the middle of this family between OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-2M7FT at 2m (7ft) and OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT at 4m (13ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
The rated power consumption is 12W (800G End)10W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 32AWG conductors, PET jacket, minimum bend radius 26.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA Rev5.1, IEEE 802.3ck, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
The HT cable carries the compatibility configuration associated with OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-3M10FT, while its mechanical assembly remains the fixed 3m (10ft) version described here. Incoming inspection, connector examination and a live link test are completed before packing. Customers with unusually old or new Generic software can request a pre-order check.
Quote HT part number OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-3M10FT with the required quantity. The 3m (10ft) length is fixed for this part number; if a different length is needed, select its corresponding page and OEM reference from the length list above. Standard HT labels and project-specific packaging are available.
No. It is manufactured by HT under our own manufacturer identity.
Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.
Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.
No. This page is dedicated to 3m (10ft) and part number OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-3M10FT. Other lengths have their own part numbers and product pages.
Before packing, our team checks the cable jacket, connector boots, latches and identification of each assembly. The cable is then secured in a loose coil and protected against dust and connector impact. Neutral packaging, customer part-number labels and project-specific carton lists can be supplied on request.
Available stock is usually packed and handed to the carrier within one to three working days. Delivery can be arranged by international express, air cargo or sea freight, with tracking details supplied after dispatch. Freight-collect shipments and delivery to a customer warehouse or forwarder can also be coordinated.
Please write to sales@huihongfiber.com, we will reply as soon as possible.
| Fiber Optic Test Equipment |
| Fiber Optic Tool Kits |
Huihong TechnologiesAdd:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,ChinaEmail:info@huihongfiber.com Tel: 86.755.61230063 Specialized fiber optic products manufacturer. |
Fiber Optic Quick Guide |
News and ExhibitionsCompany news and exhibitions schedules for this year and next year. click here for details . |
Fiber Optic Applications
|
Customer Support
|