Skip to content
You are here:

OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top to 2 x 200G QSFP56 4 x 50G PAM4 Active Optical Breakout Cable, 20m (66ft)

OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top to 2 x 200G QSFP56 4 x 50G PAM4 Active Optical Breakout Cable, 20m (66ft)

With a fixed 20m (66ft) cable and OSFP (IHS/Finned Top) to 2x QSFP56, the OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT compatible assembly simplifies 400G deployment. It is manufactured and tested by HT for multi-vendor equipment.

OEM Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FTHT Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT

Product Highlights

  • HT-manufactured AOC assembly in 20m (66ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 2x QSFP56
  • Fixed length and part number: 20m (66ft), OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 10W (OSFP End) 5.5W (QSFP56 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 2x QSFP56
Max. Data Rate400Gbps
Cable Length20m (66ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption10W (OSFP End) 5.5W (QSFP56 Per End)
Jacket MaterialOFNP
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation FormatOSFP-8x 50G-PAM4QSFP56-4x 50G-PAM4
Host FECPre-FEC BER 2.4E-4, Post-FEC BER 1E-12
Application400G/200G Ethernet
ProtocolsIEEE 802.3cd, CMIS Rev. 4.0, SFF-8679, SFF-8661, SFF-8636

Signal and Lane Configuration

The listed modulation format is OSFP-8x 50G-PAM4QSFP56-4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G/200G Ethernet. Listed interface and protocol references include IEEE 802.3cd, CMIS Rev. 4.0, SFF-8679, SFF-8661, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The extended 20m (66ft) reach supports connections across adjacent racks or between separated equipment rows. Secure the cable along its route, protect both ends from pull loads and preserve ventilation. The integrated AOC construction avoids a chain of separate modules and patch leads.

Position Within the Length Range

OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT occupies the middle of this family between OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-15M49FT at 15m (49ft) and OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT at 30m (98ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 10m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Power and Thermal Planning

The rated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Generic Compatibility and Factory Testing

For this Generic application, testing combines digital identification with actual traffic-link verification and optical link operation, receive activity and diagnostic readouts. Both ends are inspected for latch, boot and connector damage. If the project uses a specific hardware revision or a channelized port, send those details so that the intended configuration can be reviewed before shipment.

Ordering Information

When ordering, specify OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT, cable length 20m (66ft) and the host platform. This allows our team to verify both the physical assembly and the compatibility requirement before production. Neutral labeling and customer packing lists can be arranged for volume orders.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 20m (66ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

What information should I provide for a compatibility check?

Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.

Quality Assurance and Packaging

Before packing, our team checks the cable jacket, connector boots, latches and identification of each assembly. The cable is then secured in a loose coil and protected against dust and connector impact. Neutral packaging, customer part-number labels and project-specific carton lists can be supplied on request.

Shipping and Lead Time

Stock items are generally dispatched within one to three working days after order confirmation. DHL, UPS, FedEx, TNT and EMS are available for international delivery; larger consolidated orders can move by air or sea freight. Customer courier accounts and nominated forwarders are accepted.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.