With a fixed 30m (98ft) cable and OSFP (IHS/Finned Top) to 2x QSFP56, the OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT compatible assembly simplifies 400G deployment. It is manufactured and tested by HT for multi-vendor equipment.
OEM Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FTHT Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT
| HT Part Number | OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 2x QSFP56 |
| Max. Data Rate | 400Gbps |
| Cable Length | 30m (98ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Max. Power Consumption | 10W (OSFP End) 5.5W (QSFP56 Per End) |
| Jacket Material | OFNP |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | OSFP-8x 50G-PAM4QSFP56-4x 50G-PAM4 |
| Host FEC | Pre-FEC BER 2.4E-4, Post-FEC BER 1E-12 |
| Application | 400G/200G Ethernet |
| Protocols | IEEE 802.3cd, CMIS Rev. 4.0, SFF-8679, SFF-8661, SFF-8636 |
The listed modulation format is OSFP-8x 50G-PAM4QSFP56-4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The intended application is 400G/200G Ethernet. Listed interface and protocol references include IEEE 802.3cd, CMIS Rev. 4.0, SFF-8679, SFF-8661, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP (IHS/Finned Top) to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
The extended 30m (98ft) reach supports connections across adjacent racks or between separated equipment rows. Secure the cable along its route, protect both ends from pull loads and preserve ventilation. The integrated AOC construction avoids a chain of separate modules and patch leads.
OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT is the longest of 6 verified length options in this family. Compared with OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT at 20m (66ft), it provides 10m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
The rated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Each OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT compatible cable is powered up on a suitable test interface rather than checked only for continuity. We confirm the expected identification and observe optical link operation, receive activity and diagnostic readouts. Because operating systems can apply different qualification rules by hardware revision, the intended Generic platform should be included with the order.
This product is ordered as OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT in 30m (98ft). Include the equipment model and software release if you would like a pre-order compatibility review. Other lengths use different part numbers and should not be substituted into the same order line.
No. It is manufactured by HT under our own manufacturer identity.
No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.
No. Follow the specified minimum bend radius and route the 30m (98ft) assembly without tight folds, sharp edges or excessive cable ties.
Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.
HT inspects and tests every completed cable before it enters finished stock. Protective caps or covers are fitted where applicable, followed by anti-static or tray packaging and an outer carton. Custom labels can cross-reference the customer part number, OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT and the 30m (98ft) length for easier inventory control.
Lead time for ordinary configurations is normally one to three working days, while production quantities are confirmed with the order. We can arrange express courier or economy freight according to destination and carton volume, or hand the shipment to your appointed logistics provider.
Please write to sales@huihongfiber.com, we will reply as soon as possible.
| Fiber Optic Test Equipment |
| Fiber Optic Tool Kits |
Huihong TechnologiesAdd:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,ChinaEmail:info@huihongfiber.com Tel: 86.755.61230063 Specialized fiber optic products manufacturer. |
Fiber Optic Quick Guide |
News and ExhibitionsCompany news and exhibitions schedules for this year and next year. click here for details . |
Fiber Optic Applications
|
Customer Support
|