OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT 1.6T OSFP224 8 x 200G PAM4 IHS Finned Top Passive Copper Twinax Cable, 1m (3ft)

OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT 1.6T OSFP224 8 x 200G PAM4 IHS Finned Top Passive Copper Twinax Cable, 1m (3ft)

The OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT cable offers a direct OSFP (IHS Finned Top) to OSFP (IHS Finned Top) connection at 1600Gbps. Its 1m (3ft) length and DAC construction are intended for multi-vendor equipment, with no separate transceiver-and-patch-cord assembly required.

OEM Part Number: OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FTHT Part Number: OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT

Product Highlights

  • HT-manufactured DAC assembly in 1m (3ft)
  • 1.6T connectivity at 1600Gbps
  • Interface configuration: OSFP (IHS Finned Top) to OSFP (IHS Finned Top)
  • Fixed length and part number: 1m (3ft), OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT
  • Cable construction: Passive DAC
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.1W Per End
  • Minimum bend radius: 55mm

Specifications

HT Part NumberOSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT
ManufacturerHT
Form FactorOSFP (IHS Finned Top) to OSFP (IHS Finned Top)
Max. Data Rate1600Gbps
MediaCopper
Cable TypePassive DAC
Cable Length1m (3ft)
Jacket MaterialPET
Minimum Bend Radius55mm
Wire AWG26AWG
Max. Power Consumption0.1W Per End
Modulation Format8x 200G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application1.6T Ethernet
ProtocolsOSFP MSA, IEEE 802.3

Signal and Lane Configuration

The listed modulation format is 8x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

At 1m (3ft), OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT is the longest of 2 verified length options in this family. Compared with OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-0.5M2FT at 0.5m (2ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Power and Thermal Planning

The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PET jacket, minimum bend radius 55mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 1.6T Ethernet. Listed interface and protocol references include OSFP MSA, IEEE 802.3. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Generic Compatibility and Factory Testing

For this Generic application, testing combines digital identification with actual traffic-link verification and electrical continuity, link stability and diagnostic readouts. Both ends are inspected for latch, boot and connector damage. If the project uses a specific hardware revision or a channelized port, send those details so that the intended configuration can be reviewed before shipment.

Ordering Information

Use part number OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT for the 1m (3ft) assembly. For mixed-length projects, list each required part number and quantity separately so that every cable can be tested and packed according to its intended installation.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this page include more than one cable length?

No. This page is dedicated to 1m (3ft) and part number OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT. Other lengths have their own part numbers and product pages.

Are separate optical modules required?

No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 1m (3ft) assembly without tight folds, sharp edges or excessive cable ties.

Quality Assurance and Packaging

HT inspects and tests every completed cable before it enters finished stock. Protective caps or covers are fitted where applicable, followed by anti-static or tray packaging and an outer carton. Custom labels can cross-reference the customer part number, OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT and the 1m (3ft) length for easier inventory control.

Shipping and Lead Time

Lead time for ordinary configurations is normally one to three working days, while production quantities are confirmed with the order. We can arrange express courier or economy freight according to destination and carton volume, or hand the shipment to your appointed logistics provider.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.