OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top Passive Copper Twinax Cable, 1m (3ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top Passive Copper Twinax Cable, 1m (3ft)

The HT-manufactured OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT compatible cable provides 400G connectivity for multi-vendor equipment. This 1m (3ft) version is a factory-terminated passive copper link without separate optical modules or patch cords, with an exact part number and length that can be matched directly to the equipment requirement.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT

Product Highlights

  • HT-manufactured DAC assembly in 1m (3ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 1m (3ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT
  • Cable construction: Passive DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W Per End
  • Minimum bend radius: 34.5mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate400Gbps
MediaCopper
Cable TypePassive DAC
Minimum Bend Radius34.5mm
Max. Power Consumption0.1W Per End
Cable Length1m (3ft)
Wire AWG30AWG
Temperature Range0 to 70°C (32 to 158°F)
Jacket MaterialPVC
ProtocolsOSFP MSA, IEEE 802.3cd 100GBase-CR2, CMIS 4.0
Modulation Format8x 50G-PAM4

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Power and Thermal Planning

The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 34.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3cd 100GBase-CR2, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.

Generic Compatibility and Factory Testing

Each OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT compatible cable is powered up on a suitable test interface rather than checked only for continuity. We confirm the expected identification and observe electrical continuity, link stability and diagnostic readouts. Because operating systems can apply different qualification rules by hardware revision, the intended Generic platform should be included with the order.

Ordering Information

Quote HT part number OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT with the required quantity. The 1m (3ft) length is fixed for this part number; if a different length is needed, select its corresponding page and OEM reference from the length list above. Standard HT labels and project-specific packaging are available.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate optical modules required?

No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 1m (3ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

Quality Assurance and Packaging

HT inspects and tests every completed cable before it enters finished stock. Protective caps or covers are fitted where applicable, followed by anti-static or tray packaging and an outer carton. Custom labels can cross-reference the customer part number, OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-1M3FT and the 1m (3ft) length for easier inventory control.

Shipping and Lead Time

Stock items are generally dispatched within one to three working days after order confirmation. DHL, UPS, FedEx, TNT and EMS are available for international delivery; larger consolidated orders can move by air or sea freight. Customer courier accounts and nominated forwarders are accepted.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.