OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-0.5M2FT 400G OSFP 4 x 100G PAM4 RHS/Flat Top to 400G QSFP-DD 4 x 100G PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-0.5M2FT 400G OSFP 4 x 100G PAM4 RHS/Flat Top to 400G QSFP-DD 4 x 100G PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

The HT-manufactured OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-0.5M2FT compatible cable provides 400G connectivity for multi-vendor equipment. This 0.5m (2ft) version is a factory-terminated passive copper link without separate optical modules or patch cords, with an exact part number and length that can be matched directly to the equipment requirement.

OEM Part Number: OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-0.5M2FTHT Part Number: OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-0.5M2FT

Product Highlights

  • HT-manufactured DAC assembly in 0.5m (2ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (RHS/Flat Top) to QSFP-DD
  • Fixed length and part number: 0.5m (2ft), OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-0.5M2FT
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.1W
  • Minimum bend radius: 34.5mm

Specifications

HT Part NumberOSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-0.5M2FT
ManufacturerHT
Form FactorOSFP (RHS/Flat Top) to QSFP-DD
Max Data Rate400Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length0.5m (2ft)
Wire AWG30AWG
Minimum Bend Radius34.5mm
Power Consumption≤0.1W
Jacket MaterialPVC
Temperature0 to 70°C (32 to 158°F)
Application400G Ethernet
Modulation TechnologyOSFP-4x100GPAM4QDD-4x100GPAM4
ProtocolsIEEE 802.3cd, OSFP MSA, QSFP-DD MSA, CMIS Rev4.0, SFF-8417

Power and Thermal Planning

The rated power consumption is ≤0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-0.5M2FT is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-1M3FT at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 34.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include IEEE 802.3cd, OSFP MSA, QSFP-DD MSA, CMIS Rev4.0, SFF-8417. Confirm that the host firmware and port configuration support the same operating mode.

Generic Compatibility and Factory Testing

For this Generic application, testing combines digital identification with actual traffic-link verification and electrical continuity, link stability and diagnostic readouts. Both ends are inspected for latch, boot and connector damage. If the project uses a specific hardware revision or a channelized port, send those details so that the intended configuration can be reviewed before shipment.

Ordering Information

This product is ordered as OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-0.5M2FT in 0.5m (2ft). Include the equipment model and software release if you would like a pre-order compatibility review. Other lengths use different part numbers and should not be substituted into the same order line.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 0.5m (2ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

What information should I provide for a compatibility check?

Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.

Quality Assurance and Packaging

Production inspection covers both physical condition and a live link check. Connector ends receive individual protection, and the completed assembly is packed without tight ties or sharp bends. For multi-length projects, cartons can be separated and labelled by OEM part number to simplify installation on site.

Shipping and Lead Time

Lead time for ordinary configurations is normally one to three working days, while production quantities are confirmed with the order. We can arrange express courier or economy freight according to destination and carton volume, or hand the shipment to your appointed logistics provider.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.