Juniper Networks QDD-2X100G-2M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Passive Copper Breakout Cable, 2m (7ft)

Juniper Networks QDD-2X100G-2M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Passive Copper Breakout Cable, 2m (7ft)

For short, high-density connections, this DAC cable combines 200G performance with a fixed 2m (7ft) cable run. It corresponds to Juniper Networks QDD-2X100G-2M and uses a factory-terminated passive copper link without separate optical modules or patch cords.

OEM Part Number: QDD-2X100G-2MHT Part Number: QDD-2X100G-2M

Product Highlights

  • Compatible alternative to Juniper Networks QDD-2X100G-2M
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP-DD to 2x QSFP28
  • Fixed length and part number: 2m (7ft), QDD-2X100G-2M
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (QSFP28 Per End)
  • Minimum bend radius: 35mm

Specifications

HT Part NumberQDD-2X100G-2M
Juniper Networks CompatibleQDD-2X100G-2M
ManufacturerHT
Form FactorQSFP-DD to 2x QSFP28
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius35mm
Wire AWG28AWG
Cable Length2m (7ft)
Jacket MaterialPVC
Max. Power Consumption0.1W (QSFP-DD End)0.1W (QSFP28 Per End)
Modulation FormatQSFP-DD-8x 25G-NRZQSFP28-4x 25G-NRZ
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8661, IEEE 802.3bs-200GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Breakout Port Mapping

The QSFP-DD to 2x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

QDD-2X100G-2M provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

QDD-2X100G-2M occupies the middle of this family between QDD-2X100G-1M at 1m (3ft) and QDD-2X100G-3M at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 25G-NRZQSFP28-4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8661, IEEE 802.3bs-200GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Juniper Networks Compatibility and Factory Testing

Each QDD-2X100G-2M compatible cable is powered up on a suitable test interface rather than checked only for continuity. We confirm the expected identification and observe electrical continuity, link stability and diagnostic readouts. Because operating systems can apply different qualification rules by hardware revision, the intended Juniper Networks platform should be included with the order.

Ordering Information

This product is ordered as QDD-2X100G-2M in 2m (7ft). Include the equipment model and software release if you would like a pre-order compatibility review. Other lengths use different part numbers and should not be substituted into the same order line.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QDD-2X100G-2M.

What information should I provide for a compatibility check?

Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.

Does this page include more than one cable length?

No. This page is dedicated to 2m (7ft) and part number QDD-2X100G-2M. Other lengths have their own part numbers and product pages.

Are separate optical modules required?

No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.

Quality Assurance and Packaging

Quality control includes connector appearance, cable identification and functional verification. Packing materials are selected to keep the connector housings and cable boots from taking impact during transport, and the coil is not compressed into an undersized bundle. Volume orders can include customer-specific labels and packing documentation.

Shipping and Lead Time

Standard configurations normally ship within one to three working days. Worldwide courier, air freight and sea freight options are available, and shipments can also be sent on your own courier account or delivered to an appointed forwarder.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.