Juniper Networks QDD-2X100G-3M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Passive Copper Breakout Cable, 3m (10ft)

Juniper Networks QDD-2X100G-3M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Passive Copper Breakout Cable, 3m (10ft)

With a fixed 3m (10ft) cable and QSFP-DD to 2x QSFP28, the QDD-2X100G-3M compatible assembly simplifies 200G deployment. It is manufactured and tested by HT for Juniper Networks equipment.

OEM Part Number: QDD-2X100G-3MHT Part Number: QDD-2X100G-3M

Product Highlights

  • Compatible alternative to Juniper Networks QDD-2X100G-3M
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP-DD to 2x QSFP28
  • Fixed length and part number: 3m (10ft), QDD-2X100G-3M
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (QSFP28 Per End)
  • Minimum bend radius: 35mm

Specifications

HT Part NumberQDD-2X100G-3M
Juniper Networks CompatibleQDD-2X100G-3M
ManufacturerHT
Form FactorQSFP-DD to 2x QSFP28
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius35mm
Wire AWG28AWG
Cable Length3m (10ft)
Jacket MaterialPVC
Max. Power Consumption0.1W (QSFP-DD End)0.1W (QSFP28 Per End)
Modulation FormatQSFP-DD-8x 25G-NRZQSFP28-4x 25G-NRZ
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8661, IEEE 802.3bs-200GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Breakout Port Mapping

The QSFP-DD to 2x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

QDD-2X100G-3M is the longest of 4 verified length options in this family. Compared with QDD-2X100G-2M at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 25G-NRZQSFP28-4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8661, IEEE 802.3bs-200GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Juniper Networks Compatibility and Factory Testing

The HT cable carries the compatibility configuration associated with QDD-2X100G-3M, while its mechanical assembly remains the fixed 3m (10ft) version described here. Incoming inspection, connector examination and a live link test are completed before packing. Customers with unusually old or new Juniper Networks software can request a pre-order check.

Ordering Information

When ordering, specify QDD-2X100G-3M, cable length 3m (10ft) and the host platform. This allows our team to verify both the physical assembly and the compatibility requirement before production. Neutral labeling and customer packing lists can be arranged for volume orders.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QDD-2X100G-3M.

Are separate optical modules required?

No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 3m (10ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

Quality Assurance and Packaging

Production inspection covers both physical condition and a live link check. Connector ends receive individual protection, and the completed assembly is packed without tight ties or sharp bends. For multi-length projects, cartons can be separated and labelled by OEM part number to simplify installation on site.

Shipping and Lead Time

Available stock is usually packed and handed to the carrier within one to three working days. Delivery can be arranged by international express, air cargo or sea freight, with tracking details supplied after dispatch. Freight-collect shipments and delivery to a customer warehouse or forwarder can also be coordinated.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.