Skip to content
You are here:

Cisco QDD-4ZQ100-CU1.5M Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 1.5m (5ft)

Cisco QDD-4ZQ100-CU1.5M Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 1.5m (5ft)

Designed for hosts that recognize QDD-4ZQ100-CU1.5M, this QSFP-DD to 4x QSFP56 cable delivers 400G transmission over a fixed 1.5m (5ft) assembly. Its DAC construction provides a factory-terminated passive copper link without separate optical modules or patch cords.

OEM Part Number: QDD-4ZQ100-CU1.5MHT Part Number: QDD-4ZQ100-CU1.5M

Product Highlights

  • Compatible alternative to Cisco QDD-4ZQ100-CU1.5M
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 4x QSFP56
  • Fixed length and part number: 1.5m (5ft), QDD-4ZQ100-CU1.5M
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (QSFP56 Per End)
  • Minimum bend radius: 41mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQDD-4ZQ100-CU1.5M
Cisco CompatibleQDD-4ZQ100-CU1.5M
ManufacturerHT
Form FactorQSFP-DD to 4x QSFP56
Max. Data Rate400Gbps
Minimum Bend Radius41mm
Wire AWG30AWG
Cable Length1.5m (5ft)
Jacket MaterialPVC
MediaCopper
Modulation FormatQSFP-DD-8x 50G-PAM4QSFP56-2x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Power Supply3.3V
ProtocolsSFF-8665, QSFP-DD MSA, IEEE802.3bj, IEEE802.3 cd
Max. Power Consumption0.1W (QSFP-DD End)0.1W (QSFP56 Per End)
Application400G Ethernet

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 50G-PAM4QSFP56-2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include SFF-8665, QSFP-DD MSA, IEEE802.3bj, IEEE802.3 cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives QDD-4ZQ100-CU1.5M useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

QDD-4ZQ100-CU1.5M occupies the middle of this family between QDD-4ZQ100-CU1M at 1m (3ft) and QDD-4ZQ100-CU2M at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 41mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Cisco Compatibility and Factory Testing

Compatibility is more than matching the QSFP-DD to 4x QSFP56 shape. This assembly is prepared for hosts expecting QDD-4ZQ100-CU1.5M and is checked for identification, stable link behavior and electrical continuity, link stability and diagnostic readouts. We recommend confirming the equipment model and software release for critical deployments or mixed-vendor installations.

Ordering Information

When ordering, specify QDD-4ZQ100-CU1.5M, cable length 1.5m (5ft) and the host platform. This allows our team to verify both the physical assembly and the compatibility requirement before production. Neutral labeling and customer packing lists can be arranged for volume orders.

Frequently Asked Questions

Is this an original Cisco cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco QDD-4ZQ100-CU1.5M.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 1.5m (5ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

What information should I provide for a compatibility check?

Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.

Quality Assurance and Packaging

HT inspects and tests every completed cable before it enters finished stock. Protective caps or covers are fitted where applicable, followed by anti-static or tray packaging and an outer carton. Custom labels can cross-reference the customer part number, QDD-4ZQ100-CU1.5M and the 1.5m (5ft) length for easier inventory control.

Shipping and Lead Time

Available stock is usually packed and handed to the carrier within one to three working days. Delivery can be arranged by international express, air cargo or sea freight, with tracking details supplied after dispatch. Freight-collect shipments and delivery to a customer warehouse or forwarder can also be coordinated.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.