Juniper Networks QDD-8x50G-2M Compatible 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 50G PAM4 Passive Copper Breakout Cable, 2m (7ft)

Juniper Networks QDD-8x50G-2M Compatible 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 50G PAM4 Passive Copper Breakout Cable, 2m (7ft)

With a fixed 2m (7ft) cable and QSFP-DD to 8x SFP56, the QDD-8x50G-2M compatible assembly simplifies 400G deployment. It is manufactured and tested by HT for Juniper Networks equipment.

OEM Part Number: QDD-8x50G-2MHT Part Number: QDD-8x50G-2M

Product Highlights

  • Compatible alternative to Juniper Networks QDD-8x50G-2M
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 8x SFP56
  • Fixed length and part number: 2m (7ft), QDD-8x50G-2M
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (SFP56 Per End)
  • Minimum bend radius: 39.5mm

Specifications

HT Part NumberQDD-8x50G-2M
Juniper Networks CompatibleQDD-8x50G-2M
ManufacturerHT
Form FactorQSFP-DD to 8x SFP56
Max. Data Rate400Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius39.5mm
Wire AWG28AWG
Cable Length2m (7ft)
Jacket MaterialPVC (OFNR)
Max. Power Consumption0.1W (QSFP-DD End)0.1W (SFP56 Per End)
Modulation FormatQSFP-DD-8x 50G-PAM4SFP56-50G-PAM4
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8432, IEEE 802.3bs-400GAUI-8, IEEE802.3cd-50GAUI-1, CMIS 4.0, SFF-8472

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 39.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8432, IEEE 802.3bs-400GAUI-8, IEEE802.3cd-50GAUI-1, CMIS 4.0, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 8x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

QDD-8x50G-2M provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

QDD-8x50G-2M occupies the middle of this family between QDD-8x50G-1.5M at 1.5m (5ft) and QDD-8x50G-2.5M at 2.5m (8ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 50G-PAM4SFP56-50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Juniper Networks Compatibility and Factory Testing

The HT cable carries the compatibility configuration associated with QDD-8x50G-2M, while its mechanical assembly remains the fixed 2m (7ft) version described here. Incoming inspection, connector examination and a live link test are completed before packing. Customers with unusually old or new Juniper Networks software can request a pre-order check.

Ordering Information

When ordering, specify QDD-8x50G-2M, cable length 2m (7ft) and the host platform. This allows our team to verify both the physical assembly and the compatibility requirement before production. Neutral labeling and customer packing lists can be arranged for volume orders.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QDD-8x50G-2M.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 2m (7ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

What information should I provide for a compatibility check?

Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.

Quality Assurance and Packaging

Production inspection covers both physical condition and a live link check. Connector ends receive individual protection, and the completed assembly is packed without tight ties or sharp bends. For multi-length projects, cartons can be separated and labelled by OEM part number to simplify installation on site.

Shipping and Lead Time

Standard configurations normally ship within one to three working days. Worldwide courier, air freight and sea freight options are available, and shipments can also be sent on your own courier account or delivered to an appointed forwarder.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.