Skip to content
You are here:

QSFP-DD to 2x QSFP56-400G-AOC-5M16FT 400G QSFP-DD 8 x 50G PAM4 to 2 x 200G QSFP56 4 x 50G PAM4 Active Optical Breakout Cable, 5m (16ft)

QSFP-DD to 2x QSFP56-400G-AOC-5M16FT 400G QSFP-DD 8 x 50G PAM4 to 2 x 200G QSFP56 4 x 50G PAM4 Active Optical Breakout Cable, 5m (16ft)

Designed for hosts that recognize QSFP-DD to 2x QSFP56-400G-AOC-5M16FT, this QSFP-DD to 2x QSFP56 cable delivers 400G transmission over a fixed 5m (16ft) assembly. Its AOC construction provides a factory-terminated active optical link with the optical engines and fiber integrated into the assembly.

OEM Part Number: QSFP-DD to 2x QSFP56-400G-AOC-5M16FTHT Part Number: QSFP-DD to 2x QSFP56-400G-AOC-5M16FT

Product Highlights

  • HT-manufactured AOC assembly in 5m (16ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 2x QSFP56
  • Fixed length and part number: 5m (16ft), QSFP-DD to 2x QSFP56-400G-AOC-5M16FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 12W (QSFP-DD End)5.5W (QSFP56 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP-DD to 2x QSFP56-400G-AOC-5M16FT
ManufacturerHT
Form FactorQSFP-DD to 2x QSFP56
Max. Data Rate400Gbps
Cable Length5m (16ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption12W (QSFP-DD End)5.5W (QSFP56 Per End)
Modulation FormatQSFP-DD-8x 50G-PAM4QSFP56-4x 50G-PAM4
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsIEEE 802.3cd, IEEE 802.3bs, QSFP-DD MSA, SFF-8024, SFF-8679, SFF-8665, CMIS 4.0, OIF-CEI-04.0

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 50G-PAM4QSFP56-4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

The 5m (16ft) length gives QSFP-DD to 2x QSFP56-400G-AOC-5M16FT more freedom for adjacent-rack and row-end deployments. The integrated optical assembly should be supported along its route without tight bends or connector pull loads; the AOC specification and host support must still match the intended link.

Position Within the Length Range

QSFP-DD to 2x QSFP56-400G-AOC-5M16FT occupies the middle of this family between QSFP-DD to 2x QSFP56-400G-AOC-3M10FT at 3m (10ft) and QSFP-DD to 2x QSFP56-400G-AOC-7M23FT at 7m (23ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Power and Thermal Planning

The rated power consumption is 12W (QSFP-DD End)5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, IEEE 802.3bs, QSFP-DD MSA, SFF-8024, SFF-8679, SFF-8665, CMIS 4.0, OIF-CEI-04.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Generic Compatibility and Factory Testing

Compatibility is more than matching the QSFP-DD to 2x QSFP56 shape. This assembly is prepared for hosts expecting QSFP-DD to 2x QSFP56-400G-AOC-5M16FT and is checked for identification, stable link behavior and optical link operation, receive activity and diagnostic readouts. We recommend confirming the equipment model and software release for critical deployments or mixed-vendor installations.

Ordering Information

When ordering, specify QSFP-DD to 2x QSFP56-400G-AOC-5M16FT, cable length 5m (16ft) and the host platform. This allows our team to verify both the physical assembly and the compatibility requirement before production. Neutral labeling and customer packing lists can be arranged for volume orders.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate optical modules required?

No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 5m (16ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

Quality Assurance and Packaging

Every QSFP-DD to 2x QSFP56-400G-AOC-5M16FT compatible assembly undergoes link testing, compatibility verification and visual inspection. The 5m (16ft) cable is coiled without exceeding its minimum bend radius, fitted with connector protection and packed in an anti-static bag or protective tray before cartoning. Project labels and packing lists are available for volume orders.

Shipping and Lead Time

Standard configurations normally ship within one to three working days. Worldwide courier, air freight and sea freight options are available, and shipments can also be sent on your own courier account or delivered to an appointed forwarder.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.