Skip to content
You are here:

SC APC to SC APC Fiber Drop Cable, OS2, Custom Length

SC APC to SC APC Fiber Drop Cable, OS2, Custom Length

This fiber drop cable closes the last span of the FTTH access network, running from the distribution point or splice closure to the subscriber premises. Both ends are factory terminated with SC APC connectors, so the link plugs directly into the optical network terminal and the distribution hardware without field splicing. The cable is the proven flat drop construction: one OS2 9/125µm single-mode fiber of G.657.A2 bend-insensitive glass in a 2.0x5.0mm LSZH jacket, manufactured to the exact length the route requires.

Product Highlights

  • SC APC to SC APC, factory terminated and tested
  • G.657.A2 bend-insensitive fiber, 7.5mm minimum bend radius
  • Flat 2.0x5.0mm LSZH drop cable construction
  • Insertion loss ≤0.3dB, return loss ≥60dB
  • Plug-and-play installation, no field splicing required
  • Manufactured to the ordered route length

Specifications

Connector ASC APC
Connector BSC APC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber Count1 Fiber
Fiber GradeG.657.A2
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)60/40mm (Dynamic/Static)
Trunk Outside Diameter (OD)2.0x5.0mm
Breakout Outside Diameter (OD)2.0x3.0mm
Breakout Length300±50mm
Cable JacketLow Smoke Zero Halogen (LSZH)
Tensile Load400N (Short Term)
Crush Resistance500N/100mm (Short Term)
Insertion Loss≤0.3dB
Return Loss≥60dB
Attenuation at 1310nm≤0.4dB/km
Attenuation at 1550nm≤0.3dB/km
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-10 to 50°C (14 to 122°F)

The last-mile link in FTTH networks

Between the distribution point and the subscriber, the drop cable is the most frequently handled and most often replaced part of the access network. It crosses walls, window frames, conduit entries and the final indoor route to the optical network terminal. A factory-terminated drop cable turns that span into a plug-and-play link: the installer routes the cable, seats both connectors, and the subscriber is live. No splicer, no curing time and no field polishing enter the schedule, which is exactly what high-volume FTTH rollouts need.

Why APC polish matters in PON access

Access networks built on GPON and XGS-PON carry downstream video overlay and high-power optical budget on shared splitters, where reflections travel back toward every subscriber on the PON. The angled physical contact end-face of the SC APC connector keeps return loss at 60dB or better, steering reflections away from the upstream path. Mixing UPC cords into an APC-planned PON creates reflectance events that are hard to trace later, so the drop segment should follow the APC discipline of the rest of the plant.

G.657.A2 glass for real subscriber premises

The indoor part of a drop route turns around door frames, baseboards and furniture edges, and it is often stapled or clipped by installers working quickly. G.657.A2 fiber tolerates a 7.5mm bend radius at the glass level, so the tight corners of a real apartment do not add measurable loss. The flat 2.0x5.0mm construction with its parallel strength members keeps the cable lying flat against surfaces and protects the core from the crushing loads of staples and clips.

Custom length as the standard practice

Drop routes vary from a few meters in a townhouse to over a hundred meters on a rural lot, and a wrong guess in either direction costs time: too short means a replacement visit, too long means a coil of slack at the terminal. Ordering the drop cable to the measured route length removes both failure modes. The 300mm breakout at the connector ends is part of the standard build, giving enough free fiber to dress into the closure or the terminal without strain.

Length options and customization

Every drop cable in this family is manufactured to the length stated with the order rather than picked from fixed stock sizes, because last-mile routes differ from a few meters to well over a hundred. The cable is manufactured to the length stated with the order; measure the route including the vertical drops and the entry path, and allow working slack at both ends for the closure and the terminal. Specifying the measured route length avoids both the slack storage problem of an overlong cable and the strain risk of one that is too short.

Quality control and testing

Every drop cable is terminated with precision zirconia ferrule SC APC connectors and optically tested before packing: insertion loss is verified against the 0.3dB ceiling and return loss against the 60dB minimum on each assembly. End-face geometry is inspected for consistent physical contact, so the delivered cable can be plugged in and put into service without on-site rework.

Ordering and Factory Support

Refer to the SC APC to SC APC drop cable family when requesting a quotation and state the route length and quantity per length. For sealed outdoor termination at the distribution end, the hardened-connector versions of this family mate directly with IP68 terminal ports; send the site requirement with the enquiry and the factory will confirm the build before production.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.