Juniper SDD-100G-1M Compatible 100G SFP-DD 2 x 50G PAM4 Passive Copper Twinax Cable, 1m (3ft)

Juniper SDD-100G-1M Compatible 100G SFP-DD 2 x 50G PAM4 Passive Copper Twinax Cable, 1m (3ft)

For short, high-density connections, this DAC cable combines 100G performance with a fixed 1m (3ft) cable run. It corresponds to Juniper SDD-100G-1M and uses a factory-terminated passive copper link without separate optical modules or patch cords.

OEM Part Number: SDD-100G-1MHT Part Number: SDD-100G-1M

Product Highlights

  • Compatible alternative to Juniper SDD-100G-1M
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP-DD to SFP-DD
  • Fixed length and part number: 1m (3ft), SDD-100G-1M
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W
  • Minimum bend radius: 23.6mm

Specifications

HT Part NumberSDD-100G-1M
Juniper CompatibleSDD-100G-1M
ManufacturerHT
Form FactorSFP-DD to SFP-DD
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length1m (3ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius23.6mm
Wire AWG30AWG
Max. Power Consumption0.1W
Modulation Format2x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet, 128G Fibre Channel
ProtocolsSFP-DD MSA, SFP-DD MIS, IEEE 802.3cd

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Position Within the Length Range

SDD-100G-1M is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is SDD-100G-2M at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Signal and Lane Configuration

The listed modulation format is 2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 23.6mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFP-DD MSA, SFP-DD MIS, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), SDD-100G-1M is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Juniper Compatibility and Factory Testing

For this Juniper application, testing combines digital identification with actual traffic-link verification and electrical continuity, link stability and diagnostic readouts. Both ends are inspected for latch, boot and connector damage. If the project uses a specific hardware revision or a channelized port, send those details so that the intended configuration can be reviewed before shipment.

Ordering Information

Use part number SDD-100G-1M for the 1m (3ft) assembly. For mixed-length projects, list each required part number and quantity separately so that every cable can be tested and packed according to its intended installation.

Frequently Asked Questions

Is this an original Juniper cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper SDD-100G-1M.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

What information should I provide for a compatibility check?

Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.

Does this page include more than one cable length?

No. This page is dedicated to 1m (3ft) and part number SDD-100G-1M. Other lengths have their own part numbers and product pages.

Quality Assurance and Packaging

Every SDD-100G-1M compatible assembly undergoes link testing, compatibility verification and visual inspection. The 1m (3ft) cable is coiled without exceeding its minimum bend radius, fitted with connector protection and packed in an anti-static bag or protective tray before cartoning. Project labels and packing lists are available for volume orders.

Shipping and Lead Time

Stock items are generally dispatched within one to three working days after order confirmation. DHL, UPS, FedEx, TNT and EMS are available for international delivery; larger consolidated orders can move by air or sea freight. Customer courier accounts and nominated forwarders are accepted.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.