Juniper SDD-100G-2M Compatible 100G SFP-DD 2 x 50G PAM4 Passive Copper Twinax Cable, 2m (7ft)

Juniper SDD-100G-2M Compatible 100G SFP-DD 2 x 50G PAM4 Passive Copper Twinax Cable, 2m (7ft)

The HT-manufactured SDD-100G-2M compatible cable provides 100G connectivity for Juniper equipment. This 2m (7ft) version is a factory-terminated passive copper link without separate optical modules or patch cords, with an exact part number and length that can be matched directly to the equipment requirement.

OEM Part Number: SDD-100G-2MHT Part Number: SDD-100G-2M

Product Highlights

  • Compatible alternative to Juniper SDD-100G-2M
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP-DD to SFP-DD
  • Fixed length and part number: 2m (7ft), SDD-100G-2M
  • Cable construction: Passive Twinax
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W
  • Minimum bend radius: 25.2mm

Specifications

HT Part NumberSDD-100G-2M
Juniper CompatibleSDD-100G-2M
ManufacturerHT
Form FactorSFP-DD to SFP-DD
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length2m (7ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius25.2mm
Wire AWG28AWG
Max. Power Consumption0.1W
Modulation Format2x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet, 128G Fibre Channel
ProtocolsSFP-DD MSA, SFP-DD MIS, IEEE 802.3cd

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

SDD-100G-2M provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

SDD-100G-2M occupies the middle of this family between SDD-100G-1M at 1m (3ft) and SDD-100G-3M at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Signal and Lane Configuration

The listed modulation format is 2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 25.2mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFP-DD MSA, SFP-DD MIS, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Juniper Compatibility and Factory Testing

The assembly is configured for equipment that recognizes SDD-100G-2M. Before shipment, we inspect both connectors and verify identification, link establishment and electrical continuity, link stability and diagnostic readouts. Host hardware and firmware revisions can affect third-party cable acceptance, so customers can provide the equipment model and software release for a pre-order compatibility review.

Ordering Information

Use part number SDD-100G-2M for the 2m (7ft) assembly. For mixed-length projects, list each required part number and quantity separately so that every cable can be tested and packed according to its intended installation.

Frequently Asked Questions

Is this an original Juniper cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper SDD-100G-2M.

Does this page include more than one cable length?

No. This page is dedicated to 2m (7ft) and part number SDD-100G-2M. Other lengths have their own part numbers and product pages.

Are separate optical modules required?

No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 2m (7ft) assembly without tight folds, sharp edges or excessive cable ties.

Quality Assurance and Packaging

Before packing, our team checks the cable jacket, connector boots, latches and identification of each assembly. The cable is then secured in a loose coil and protected against dust and connector impact. Neutral packaging, customer part-number labels and project-specific carton lists can be supplied on request.

Shipping and Lead Time

Lead time for ordinary configurations is normally one to three working days, while production quantities are confirmed with the order. We can arrange express courier or economy freight according to destination and carton volume, or hand the shipment to your appointed logistics provider.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.