Juniper SDD-Q56-DAC-3M Compatible 100G SFP-DD 2 x 50G PAM4 to QSFP56 2 x 50G PAM4 Passive Copper Twinax Cable, 3m (10ft)

Juniper SDD-Q56-DAC-3M Compatible 100G SFP-DD 2 x 50G PAM4 to QSFP56 2 x 50G PAM4 Passive Copper Twinax Cable, 3m (10ft)

The HT-manufactured SDD-Q56-DAC-3M compatible cable provides 100G connectivity for Juniper equipment. This 3m (10ft) version is a factory-terminated passive copper link without separate optical modules or patch cords, with an exact part number and length that can be matched directly to the equipment requirement.

OEM Part Number: SDD-Q56-DAC-3MHT Part Number: SDD-Q56-DAC-3M

Product Highlights

  • Compatible alternative to Juniper SDD-Q56-DAC-3M
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP-DD to QSFP56
  • Fixed length and part number: 3m (10ft), SDD-Q56-DAC-3M
  • Cable construction: Passive Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.1W
  • Minimum bend radius: 22.4mm

Specifications

HT Part NumberSDD-Q56-DAC-3M
Juniper CompatibleSDD-Q56-DAC-3M
ManufacturerHT
Form FactorSFP-DD to QSFP56
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length3m (10ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius22.4mm
Wire AWG26AWG
Max. Power Consumption0.1W
Modulation FormatSFP-DD-2x 50G-PAM4QSFP56-2x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet, 128G Fibre Channel
ProtocolsSFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdQSFP56: SFF-8661, SFF-8636, IEEE 802.3cd

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

SDD-Q56-DAC-3M is the longest of 3 verified length options in this family. Compared with SDD-Q56-DAC-2M at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Signal and Lane Configuration

The listed modulation format is SFP-DD-2x 50G-PAM4QSFP56-2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 22.4mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdQSFP56: SFF-8661, SFF-8636, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Juniper Compatibility and Factory Testing

Compatibility is more than matching the SFP-DD to QSFP56 shape. This assembly is prepared for hosts expecting SDD-Q56-DAC-3M and is checked for identification, stable link behavior and electrical continuity, link stability and diagnostic readouts. We recommend confirming the equipment model and software release for critical deployments or mixed-vendor installations.

Ordering Information

This product is ordered as SDD-Q56-DAC-3M in 3m (10ft). Include the equipment model and software release if you would like a pre-order compatibility review. Other lengths use different part numbers and should not be substituted into the same order line.

Frequently Asked Questions

Is this an original Juniper cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper SDD-Q56-DAC-3M.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

What information should I provide for a compatibility check?

Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.

Does this page include more than one cable length?

No. This page is dedicated to 3m (10ft) and part number SDD-Q56-DAC-3M. Other lengths have their own part numbers and product pages.

Quality Assurance and Packaging

Every SDD-Q56-DAC-3M compatible assembly undergoes link testing, compatibility verification and visual inspection. The 3m (10ft) cable is coiled without exceeding its minimum bend radius, fitted with connector protection and packed in an anti-static bag or protective tray before cartoning. Project labels and packing lists are available for volume orders.

Shipping and Lead Time

Available stock is usually packed and handed to the carrier within one to three working days. Delivery can be arranged by international express, air cargo or sea freight, with tracking details supplied after dispatch. Freight-collect shipments and delivery to a customer warehouse or forwarder can also be coordinated.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.