SFP-DD to 2x SFP56-100G-DAC-1M3FT 100G SFP-DD 2 x 50G PAM4 to 2 x SFP56 50G PAM4 Passive Copper Twinax Cable, 1m (3ft)

SFP-DD to 2x SFP56-100G-DAC-1M3FT 100G SFP-DD 2 x 50G PAM4 to 2 x SFP56 50G PAM4 Passive Copper Twinax Cable, 1m (3ft)

This 1m (3ft) DAC cable is built for multi-vendor equipment requiring the SFP-DD to 2x SFP56-100G-DAC-1M3FT interface. The 100Gbps link uses SFP-DD to 2x SFP56 and is supplied as one complete tested assembly.

OEM Part Number: SFP-DD to 2x SFP56-100G-DAC-1M3FTHT Part Number: SFP-DD to 2x SFP56-100G-DAC-1M3FT

Product Highlights

  • HT-manufactured DAC assembly in 1m (3ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP-DD to 2x SFP56
  • Fixed length and part number: 1m (3ft), SFP-DD to 2x SFP56-100G-DAC-1M3FT
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W
  • Minimum bend radius: 23.6mm

Specifications

HT Part NumberSFP-DD to 2x SFP56-100G-DAC-1M3FT
ManufacturerHT
Form FactorSFP-DD to 2x SFP56
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length1m (3ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius23.6mm
Wire AWG30AWG
Max. Power Consumption0.1W
Modulation FormatSFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet, 128G Fibre Channel
ProtocolsSFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is SFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), SFP-DD to 2x SFP56-100G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

SFP-DD to 2x SFP56-100G-DAC-1M3FT occupies the middle of this family between SFP-DD to 2x SFP56-100G-DAC-0.5M2FT at 0.5m (2ft) and SFP-DD to 2x SFP56-100G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Power and Thermal Planning

The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 23.6mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The SFP-DD to 2x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Generic Compatibility and Factory Testing

Our compatibility setup for Generic SFP-DD to 2x SFP56-100G-DAC-1M3FT is checked together with the physical 1m (3ft) assembly. Factory verification covers connector condition, host identification, error-free link establishment and electrical continuity, link stability and diagnostic readouts. Providing the exact host model and firmware release helps us identify platform-specific requirements before production.

Ordering Information

This product is ordered as SFP-DD to 2x SFP56-100G-DAC-1M3FT in 1m (3ft). Include the equipment model and software release if you would like a pre-order compatibility review. Other lengths use different part numbers and should not be substituted into the same order line.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this page include more than one cable length?

No. This page is dedicated to 1m (3ft) and part number SFP-DD to 2x SFP56-100G-DAC-1M3FT. Other lengths have their own part numbers and product pages.

Are separate optical modules required?

No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 1m (3ft) assembly without tight folds, sharp edges or excessive cable ties.

Quality Assurance and Packaging

Before packing, our team checks the cable jacket, connector boots, latches and identification of each assembly. The cable is then secured in a loose coil and protected against dust and connector impact. Neutral packaging, customer part-number labels and project-specific carton lists can be supplied on request.

Shipping and Lead Time

Standard configurations normally ship within one to three working days. Worldwide courier, air freight and sea freight options are available, and shipments can also be sent on your own courier account or delivered to an appointed forwarder.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.