Use the DAC-Q28-4SFP28-25G-2.5M compatible assembly where a 100G connection is required between compatible ports. This page covers the 2.5m (8ft) version only, with its own HT part number, specifications and compatibility verification.
OEM Part Number: DAC-Q28-4SFP28-25G-2.5MHT Part Number: DAC-Q28-4SFP28-25G-2.5M
| HT Part Number | DAC-Q28-4SFP28-25G-2.5M |
|---|---|
| Dell (DE) Compatible | DAC-Q28-4SFP28-25G-2.5M |
| Manufacturer | HT |
| Form Factor | QSFP28 to SFP28 |
| Max Data Rate | 100Gbps |
| Cable Type | Passive Twinax |
| Cable Length | 2.5m (8ft) |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 60mm |
| Power Consumption | ≤0.125W |
| Power Supply | 3.3V |
| MTBF | =50 Million Hours |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ |
| Media | Copper |
| Application | 100G to 4x 25G Ethernet, Data Centers |
| Protocols | IEEE 802.3, QSFP28 MSA, SFF-8665 |
The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that DAC-Q28-4SFP28-25G-2.5M reaches both ports without tension at either connector.
DAC-Q28-4SFP28-25G-2.5M occupies the middle of this family between DAC-Q28-4SFP28-25G-2M at 2m (7ft) and DAC-Q28-4SFP28-25G-3M at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
For this Dell (DE) application, testing combines digital identification with actual traffic-link verification and electrical continuity, link stability and diagnostic readouts. Both ends are inspected for latch, boot and connector damage. If the project uses a specific hardware revision or a channelized port, send those details so that the intended configuration can be reviewed before shipment.
Quote HT part number DAC-Q28-4SFP28-25G-2.5M with the required quantity. The 2.5m (8ft) length is fixed for this part number; if a different length is needed, select its corresponding page and OEM reference from the length list above. Standard HT labels and project-specific packaging are available.
No. It is an HT-manufactured compatible alternative for equipment that specifies Dell (DE) DAC-Q28-4SFP28-25G-2.5M.
No. Follow the specified minimum bend radius and route the 2.5m (8ft) assembly without tight folds, sharp edges or excessive cable ties.
Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.
Provide the host manufacturer, equipment model, port type, hardware revision and software release, together with the OEM part number and required quantity.
Before packing, our team checks the cable jacket, connector boots, latches and identification of each assembly. The cable is then secured in a loose coil and protected against dust and connector impact. Neutral packaging, customer part-number labels and project-specific carton lists can be supplied on request.
Lead time for ordinary configurations is normally one to three working days, while production quantities are confirmed with the order. We can arrange express courier or economy freight according to destination and carton volume, or hand the shipment to your appointed logistics provider.
Please write to sales@huihongfiber.com, we will reply as soon as possible.
| Fiber Optic Test Equipment |
| Fiber Optic Tool Kits |
Huihong TechnologiesAdd:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,ChinaEmail:info@huihongfiber.com Tel: 86.755.61230063 Specialized fiber optic products manufacturer. |
Fiber Optic Quick Guide |
News and ExhibitionsCompany news and exhibitions schedules for this year and next year. click here for details . |
Fiber Optic Applications
|
Customer Support
|