LC to LC Duplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

LC to LC Duplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

This duplex armored patch cable pairs two LC UPC connectors on an OS2 9/125µm single-mode assembly protected by a helical stainless steel tube. The 3.0mm riser-rated (OFCR) jacket keeps the cable flexible enough for cabinet and under-floor routing while the steel armor absorbs crushing, pulling and rodent damage that would interrupt an ordinary patch cord. G.657.A1 bend-insensitive glass keeps attenuation stable even where the pathway turns tightly around trays and rack posts.

Product Highlights

  • LC UPC to LC UPC duplex, OS2 9/125µm single mode
  • Helical stainless steel armor against crush, impact and rodents
  • G.657.A1 bend-insensitive fiber, 10/5D dynamic/static bend radius
  • Riser (OFCR) flame rating for vertical building pathways
  • Insertion loss ≤0.3dB, return loss ≥50dB
  • Stock lengths 1m to 30m; custom lengths and jackets on request

Specifications

Connector TypeLC to LC
Polish TypeUPC to UPC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountDuplex
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mm
Flame RatingRiser (OFCR)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥50dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158°F)

Why steel armor instead of a conduit

Conventional patch cords depend on the surrounding duct or tray for mechanical protection. Where cables cross open floors, shared ceilings or industrial spaces, that protection is not always available. The helical steel tube inside this assembly wraps the buffered fibers directly, so the cable itself carries the crush and rodent resistance. Installers can route it through areas that would otherwise require metal conduit, which reduces both material cost and installation time while keeping the pathway smaller and easier to reconfigure later.

OS2 single-mode performance in duplex links

OS2 glass at 1310/1550nm supports the long-reach single-mode optics used in campus backbones, carrier access networks and data center interconnects. The duplex LC interface is the standard connection for SFP, SFP+, SFP28, QSFP+ and QSFP28 transceivers, so one cable family covers links from 1G through 100G and beyond. G.657.A1 bend tolerance is fully compatible with legacy G.652.D plant, which means the cable can be mixed into existing single-mode infrastructure without changing loss budgets.

Understanding the OFCR riser rating

OFCR stands for optical fiber conductive riser: a riser-rated cable whose metallic armor makes it conductive under building codes. The riser rating permits vertical runs between floors in shafts and riser closets. Where the pathway passes through air-handling spaces, a plenum (OFNP) version should be selected instead; where low smoke and zero halogen are specified, the LSZH variant of this same LC-LC construction is available. Matching the jacket to the building section is part of the ordering discussion, not an afterthought.

Length options and customization

Standard lengths are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack and rack-to-frame connections in equipment rooms and data centers. Custom lengths beyond this range are manufactured to order, and the same construction can also be supplied with black or white jackets, APC polish, or alternative connectors through the customized duplex armored cable program. Specifying the exact route length avoids both the slack storage problem of an overlong cord and the strain risk of one that is too short, so if your link falls between two stock sizes, simply tell us the distance and we build to it.

Quality control and testing

Every assembly is terminated with precision zirconia ferrule connectors and measured for insertion loss and return loss before packing. The 0.3dB insertion loss ceiling and 50dB minimum return loss are verified values, not design targets. End-face geometry is checked to keep the physical contact consistent across repeat mating, and the ferrules are rated for up to one thousand insertion cycles, which matters in patching fields that are reconfigured frequently.

Ordering and Factory Support

Refer to the LC-LC OS2 duplex armored family when requesting a quotation and state the route length, jacket rating and connector polish required. For non-standard combinations of length, color, connector or jacket, send the requirement with the enquiry and the factory will confirm the manufacturable specification before production.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.