For site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. LC UPC Duplex OS2 Shuttered Fiber Adapter without Flange couples two LC/UPC connectors into one continuous optical route. Inside the housing, a zirconia ceramic sleeve holds both ferrules on a common axis, keeping insertion loss low and reliably repeatable across hundreds of mating cycles. The flangeless housing snaps into the rack-mounted panel cutout, saving the screw hardware and speeding up panel unit. An internal shutter closes automatically when the connector being used is withdrawn, blocking dust and protecting eyes from exposed laser light.
| Connector Type | LC-LC |
|---|---|
| Body Style | Duplex |
| Polish Type | UPC |
| Fiber Mode | OS2 9/125μm |
| Insertion Loss | ≤0.2dB |
| Durability | 1000 times |
| Mounting Type | Reduced Flanged |
| Color | Blue |
| Flammability Rate | UL 94V-0 |
| RoHS Compliancy Status | Compliant |
| Operating Temperature | -40 to 85℃(-40 to 185℉) |
| Storage Temperature | -10 to 60℃(14 to 140℉) |
| Connector Type | LC/UPC |
| Body Style | Duplex |
| Fiber Mode | SM OS2 |
| Insertion Loss | ≤0.2dB |
Two sleeve materials dominate the optical adapter market. Zirconia ceramic sleeves give the tightest alignment and are the correct option for single-mode and high-operation multimode work, where core geometry leaves no room for eccentricity. Phosphor bronze sleeves serve legacy multimode and metallic-ferrule connectors where the tolerance specification is looser and the cost matters more. Matching the sleeve to the application keeps both operation and budget under control.
Adapter panels are standardized around a handful of footprints, and the SC simplex footprint is the most common: duplex LC adapters are built to drop into the identical cutout, which is why LC and SC positions interchange freely on modern frames. Keeping to the standard footprint matters when a panel is re-loaded years later - the replacement adapter must fit the hole that is already there.
The optical adapter has no polish of its own, but it is where polish discipline succeeds or fails: mating a UPC connector to an APC connector through any adapter damages both end faces and wrecks return loss. Color coding exists to prevent exactly that - green housings for APC, blue for UPC single-mode - and the discipline only works when the whole plant follows it. Keep the optical adapter color, the connector being used boot color and the documentation consistent, and the mixing mistake becomes nearly impossible.
An open adapter port is an invitation to dust, and dust on a ferrule end face is the single most common cause of unexplained loss. A shuttered adapter closes an internal flap the moment the connector being used withdraws, keeping the sleeve bore clean until the next mating. The identical shutter blocks the direct line of sight into a live port, a small but real safety gain where high-power transmitters are in service. Shuttered versions cost slightly more and repay it the first time a port stays clean through a long build phase.
An adapter contributes no signal of its own; thus, its test is a mating test: reference connectors mate through the optical adapter, and the inserted loss is recorded. A zirconia-sleeve adapter should add no more than 0.2 dB, and the mating must repeat that figure across cycles. Durability testing runs the mating hundreds of times and re-measures - a sleeve that wears loose announces itself as creeping loss. These figures, not the housing color, are what separates an adapter that serves for years from one that becomes the mystery fault.
Five decisions define the optical adapter order: the connector being used pairing should be matched to both sides of the mating, the mounting style must fit the rack-mounted panel cutout, the polish color code should be matched to the plant, the sleeve material must suit the operation grade, and the count must cover the load-out plus spares. Getting all five right at order time is what turns a bag of couplers into a dependable panel. Where the pairing crosses connector families, the hybrid range covers the common conversions.
Every adapter is inspected before packing: the sleeve bore is checked for alignment and surface finish, the housing latches are cycled for positive engagement, and sample matings from each production lot are measured for insertion loss. Accessories are checked for fit against the adapters they serve. Keep this requirement with the field checklist and the delivered product records.
Refer to this adapter by connector pairing, mounting style, polish grade and pack number of units when purchasing a quotation. For configurations outside the listed options - mixed packs, panel hardware kits or project packaging - send the specification with the request and the factory will ensure the manufacturable specification. The order details should include any site identification needed by the installation team.
Please write to sales@huihongfiber.com, we will reply as soon as possible.
| Fiber Optic Test Equipment |
| Fiber Optic Tool Kits |
Huihong TechnologiesAdd:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,ChinaEmail:info@huihongfiber.com Tel: 86.755.61230063 Specialized fiber optic products manufacturer. |
Fiber Optic Quick Guide |
News and ExhibitionsCompany news and exhibitions schedules for this year and next year. click here for details . |
Fiber Optic Applications
|
Customer Support
|