MMC-16 to MTP-16 APC Jumper, 16 Fibers, OM4

MMC-16 to MTP-16 APC Jumper, 16 Fibers, OM4

This MMC-16 to MTP-16 jumper connects two different multi-fiber form factors over sixteen OM4 fibers. The MMC end and MTP Elite end are both APC female, and the bend-insensitive multimode cable uses a 2.5mm plenum jacket. It offers a direct, compact patching option between MMC infrastructure and existing MTP-16 multimode hardware.

Product Highlights

  • MMC Female to MTP® Female, 16 Fibers
  • OM4 50/125µm, bend-insensitive fiber
  • MMC insertion loss ≤0.35dB, return loss ≥40/45dB (MMC/MTP®)
  • Jumper Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number16FMMCMTPOM4
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Polish TypeAPC to APC
Glass FiberBend Insensitive Fiber
Fiber ModeOM4 50/125µm
Wavelength850/1300nm
Fiber Count16 Fibers
PolarityJumper Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥40/45dB (MMC/MTP®)
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-10 to 70°C (14 to 158°F)

Practical role in a multimode channel

The assembly suits migrations where MMC panels are being introduced without replacing every MTP-based connection. A single factory-built jumper avoids an extra adapter pair that would otherwise be needed to convert form factors. It remains essential to check that the active equipment or cassette presents the correct pinned mates and that the channel requires APC at both ends.

Connector-specific return-loss requirements

The MMC interface is specified for at least 40dB return loss, while the MTP APC interface is specified for at least 45dB; maximum insertion loss across the assembly is 0.35dB. Keeping separate connector values in the documentation makes troubleshooting more meaningful. OM4 attenuation is 2.3dB/km at 850nm and 0.6dB/km at 1300nm, with actual system reach set by the optics.

Installation length and cable care

Choose from 1m (3ft), 2m (7ft) and 3m (10ft) standard versions, or request a custom meter or foot length. Do not pull the assembly by either connector boot during routing. Support the 2.5mm cable through the manager, retain the 7.5mm fiber bend allowance and keep dust caps fitted until both end faces have been inspected.

Ordering and Factory Support

Order by part number 16FMMCMTPOM4 with length and quantity. Custom labels can identify the MMC and MTP ends separately, which is helpful when several transition cords occupy the same panel; request this labeling when submitting the order.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.