SFP28 to SFP28-25G-DAC-0.5M2FT 25G SFP28 Passive Copper Twinax Cable, 0.5m (2ft)

SFP28 to SFP28-25G-DAC-0.5M2FT 25G SFP28 Passive Copper Twinax Cable, 0.5m (2ft)

Designed for hosts that recognize SFP28 to SFP28-25G-DAC-0.5M2FT, this SFP28 to SFP28 cable delivers 25G transmission over a fixed 0.5m (2ft) assembly. Its DAC construction provides a factory-terminated passive copper link without separate optical modules or patch cords.

OEM Part Number: SFP28 to SFP28-25G-DAC-0.5M2FTHT Part Number: SFP28 to SFP28-25G-DAC-0.5M2FT

Product Highlights

  • HT-manufactured DAC assembly in 0.5m (2ft)
  • 25G connectivity at 25Gbps
  • Interface configuration: SFP28 to SFP28
  • Fixed length and part number: 0.5m (2ft), SFP28 to SFP28-25G-DAC-0.5M2FT
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.5W
  • Minimum bend radius: 21mm

Specifications

HT Part NumberSFP28 to SFP28-25G-DAC-0.5M2FT
ManufacturerHT
Connector TypeSFP28 to SFP28
Max. Data Rate25Gbps
Cable TypePassive Twinax
Cable Length0.5m (1.64ft)
MediaCopper
Wire AWG30AWG
Minimum Bend Radius21mm
Power Consumption≤0.5W
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
Power Supply3.3V
Application25G Ethernet, Data Center, 5G Wireless
ProtocolsIEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000

Power and Thermal Planning

The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing SFP28 to SFP28-25G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 21mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 25G Ethernet, Data Center, 5G Wireless. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000. Confirm that the host firmware and port configuration support the same operating mode.

Generic Compatibility and Factory Testing

Each SFP28 to SFP28-25G-DAC-0.5M2FT compatible cable is powered up on a suitable test interface rather than checked only for continuity. We confirm the expected identification and observe electrical continuity, link stability and diagnostic readouts. Because operating systems can apply different qualification rules by hardware revision, the intended Generic platform should be included with the order.

Ordering Information

Quote HT part number SFP28 to SFP28-25G-DAC-0.5M2FT with the required quantity. The 0.5m (2ft) length is fixed for this part number; if a different length is needed, select its corresponding page and OEM reference from the length list above. Standard HT labels and project-specific packaging are available.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate optical modules required?

No. The connectors and cable form one complete direct-attach assembly. Do not attempt to detach or replace either end.

Can the cable be folded to shorten its routing path?

No. Follow the specified minimum bend radius and route the 0.5m (2ft) assembly without tight folds, sharp edges or excessive cable ties.

Can I use it between different speeds or interface types?

Only when both hosts explicitly support the same data rate, lane mapping and breakout configuration. Mechanical fit alone is not proof of interoperability.

Quality Assurance and Packaging

Quality control includes connector appearance, cable identification and functional verification. Packing materials are selected to keep the connector housings and cable boots from taking impact during transport, and the coil is not compressed into an undersized bundle. Volume orders can include customer-specific labels and packing documentation.

Shipping and Lead Time

Lead time for ordinary configurations is normally one to three working days, while production quantities are confirmed with the order. We can arrange express courier or economy freight according to destination and carton volume, or hand the shipment to your appointed logistics provider.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.