MMC-16 to MMC-16 APC Jumper, 16 Fibers, OM4

MMC-16 to MMC-16 APC Jumper, 16 Fibers, OM4

This OM4 version of the MMC-16 to MMC-16 jumper carries sixteen multimode fibers between two APC female MMC connectors. Its 2.5mm magenta-family plenum construction is suited to dense in-rack and row-level cabling, while bend-insensitive OM4 glass supports 850/1300nm multimode links. The factory-terminated design removes field polishing from a sixteen-fiber installation.

Product Highlights

  • MMC Female to MMC Female, 16 Fibers
  • OM4 50/125µm, bend-insensitive fiber
  • MMC insertion loss ≤0.35dB, return loss ≥40dB
  • Jumper Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number16FMMCOM4
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MMC Female (Non-Pinned)
Polish TypeAPC to APC
Glass FiberBend Insensitive Fiber
Fiber ModeOM4 50/125µm
Wavelength850/1300nm
Fiber Count16 Fibers
PolarityJumper Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥40dB
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-10 to 70°C (14 to 158°F)

A compact multimode patching interface

The jumper is designed for MMC-based panels and equipment interfaces that need sixteen fibers in one small connection. Both cable ends are non-pinned females and must mate with the appropriate pinned interface. Compared with breaking the link into eight separate duplex cords, a single MMC jumper can simplify dressing and port identification, provided the connected equipment is designed around the same fiber map.

OM4 loss and reflection values

Maximum insertion loss is 0.35dB and minimum return loss is 40dB for this OM4 APC assembly. The specified attenuation is 2.3dB/km at 850nm and 0.6dB/km at 1300nm. These are cable and connector characteristics, not a promise of transceiver reach; the permissible link length still depends on the optical module, wavelength and total number of mated connections.

Choosing the length and managing the boot

Available standard lengths are 1m (3ft), 2m (7ft) and 3m (10ft), and custom meter or foot lengths can be manufactured. Select a length that reaches the route without leaving a tight coil behind the panel. Maintain the 7.5mm minimum optical-fiber bend radius and observe the stated cable bend limits, particularly where several VSFF jumpers share one manager.

Ordering and Factory Support

When ordering 16FMMCOM4, state the length, quantity and any project labels. If the link includes MMC-to-MTP cords or a breakout elsewhere, send the channel drawing so fiber mode and polarity can be checked as one system.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.