MMC-16 to MTP-16 APC Jumper, 16 Fibers, OS2

MMC-16 to MTP-16 APC Jumper, 16 Fibers, OS2

The 16FMMCMTPSMF jumper provides a direct transition from a compact MMC-16 APC female connector to an MTP-16 APC Elite female connector. Sixteen OS2 G.657.A1 fibers run through the 2.5mm OFNP cable, allowing newer MMC infrastructure to connect with established MTP-based panels or equipment without adding a cassette between the two interfaces.

Product Highlights

  • MMC Female to MTP® Female, 16 Fibers
  • OS2 9/125µm, G.657.A1
  • MMC insertion loss ≤0.35dB, return loss ≥60dB
  • Jumper Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number16FMMCMTPSMF
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Polish TypeAPC to APC
Glass FiberG.657.A1
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber Count16 Fibers
PolarityJumper Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥60dB
Attenuation at 1310nm≤0.35dB/km
Attenuation at 1550nm≤0.21dB/km
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-10 to 70°C (14 to 158°F)

Using the MMC-to-MTP transition

This cord is useful when one side of a channel has adopted VSFF MMC connectivity and the other remains MTP-16. It reduces the number of intermediate components, but it does not change the connector gender: both ends are female and non-pinned. Confirm that the mating MMC and MTP interfaces supply guide pins and that both sides use APC polish before installation.

One jumper, two connector form factors

Although the optical fiber count is the same at both ends, the MMC and MTP housings have different physical dimensions and keying features. Technicians should identify each end before routing so the correct connector reaches the correct panel. Factory jumper polarity defines the fiber map across the assembly; any additional trunk or adapter must preserve the intended transmit-to-receive paths.

Length selection and single-mode verification

The standard range is 1m (3ft), 2m (7ft) and 3m (10ft), with custom lengths in meters or feet. Insertion loss is limited to 0.35dB and return loss is at least 60dB. Production testing should be complemented by incoming end-face inspection, because dust on either the MMC or MTP ferrule can compromise an otherwise correctly manufactured transition cord.

Ordering and Factory Support

Reference 16FMMCMTPSMF and specify the required length and quantity. For mixed MMC/MTP channels, include the equipment and panel connector genders in your enquiry so the factory can flag any interface mismatch before the cords are built.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.