16 Fibers MMC Female Type 1 Fiber Loopback Module, OS2

16 Fibers MMC Female Type 1 Fiber Loopback Module, OS2

The LPM-SM-16MMC is a 16-fiber OS2 loopback with an MMC female APC interface and Type 1 fiber mapping. It returns transmitted optical lanes to the receive side for port testing and burn-in. The assembly uses G.657.A2 fiber in a 2.5mm plenum cable, with a 100mm loop and 250mm overall length for convenient handling in laboratory and field diagnostics.

Product Highlights

  • Fiber Type: OS2 9/125µm
  • Fiber Connector: MMC Female, APC
  • Glass Fiber: G.657.A2
  • Cable Jacket: Plenum (OFNP)
  • Fiber Count: 16 Fibers
  • Fiber Mapping: Type 1

Specifications

Part NumberLPM-SM-16MMC
ManufacturerHT
Fiber TypeOS2 9/125µm
Fiber ConnectorMMC Female, APC
Glass FiberG.657.A2
Cable JacketPlenum (OFNP)
Fiber Count16 Fibers
Fiber MappingType 1
Insertion loss≤0.7dB
Return Loss≥60dB
Cable Outside Diameter (OD)2.5mm
Mating Durability50 cycles
Loop Length100mm (+0/-25mm)
Overall Length250mm (+50/-0mm)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Operation temperature0 to 60°C (32 to 140°F)
Storage Temperature-20 to 75°C (-4 to 167°F)

Type 1 mapping for sixteen-fiber tests

The loopback's internal wiring determines which transmit lanes return to which receive lanes. Type 1 must match the equipment test plan; selecting a module by connector shape alone is not sufficient. The female MMC interface requires the appropriate pinned mate, and APC polish must be consistent with the port being tested.

Optical values to consider during diagnosis

Maximum insertion loss is 0.7dB and minimum return loss is 60dB. The loopback adds passive attenuation to the test path, so review transmitter power and receiver thresholds before interpreting results. It can help isolate port behavior and support burn-in, but it does not validate the loss, polarity or end-face condition of the external cabling channel.

Handling a short precision assembly

The 100mm loop has a +0/-25mm tolerance and the 250mm overall length has a +50/-0mm tolerance. Mating durability is specified at 50 cycles. Avoid tight bends below the 7.5mm optical-fiber minimum, inspect the MMC ferrule before each use and store the module dust-capped between test sessions.

Ordering and Factory Support

Request LPM-SM-16MMC for the 16-fiber OS2 Type 1 configuration. State quantity and any identification labels required for a test kit; if your procedure uses a different mapping or fiber mode, confirm that requirement before ordering.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.