24 Fibers MMC Female Type 1 Fiber Loopback Module, OM4

24 Fibers MMC Female Type 1 Fiber Loopback Module, OM4

This 24-fiber OM4 loopback terminates in an MMC female APC connector and uses Type 1 fiber mapping to return transmitted lanes to the receiver. It supports multimode port diagnostics and burn-in without a second active device. The short 250mm assembly incorporates a 100mm fiber loop, G.657.A2 glass and a 2.5mm plenum jacket.

Product Highlights

  • Fiber Type: OM4 Multimode
  • Fiber Connector: MMC Female, APC
  • Glass Fiber: G.657.A2
  • Cable Jacket: Plenum (OFNP)
  • Fiber Count: 24 Fibers
  • Fiber Mapping: Type 1

Specifications

Part NumberLPM-OM4-24MMC
ManufacturerHT
Fiber TypeOM4 Multimode
Fiber ConnectorMMC Female, APC
Glass FiberG.657.A2
Cable JacketPlenum (OFNP)
Fiber Count24 Fibers
Fiber MappingType 1
Insertion loss≤0.7dB
Return Loss≥40dB
Cable Outside Diameter (OD)2.5mm
Mating Durability50 cycles
Loop Length100mm (+0/-25mm)
Overall Length250mm (+50/-0mm)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Operation temperature0 to 60°C (32 to 140°F)
Storage Temperature-20 to 75°C (-4 to 167°F)

OM4 and 24-fiber mapping in one test module

Both fiber mode and fiber count must match the equipment test plan. Type 1 mapping defines the return paths, while the female APC MMC interface must connect to the appropriate pinned APC mate. Keep this module separate from OS2 and 16-fiber versions so a visually similar connector does not lead to an invalid test configuration.

Interpreting results with passive loop loss

Maximum insertion loss is 0.7dB and minimum return loss is 40dB. The loop's attenuation is part of the optical path seen by the receiver and should be considered before drawing conclusions about a marginal port. Use the module for controlled port checks, then verify the installed channel separately with its actual passive components.

Storage and repeated test cycles

The module is specified for 50 mating cycles. Its loop and overall length have defined mechanical tolerances, but those dimensions do not permit sharp bending or pulling by the cable. Clean the ferrule before use, respect the 7.5mm optical-fiber bend minimum and fit the dust cap immediately after the test.

Ordering and Factory Support

Reference LPM-OM4-24MMC when requesting the 24-fiber OM4 Type 1 loopback. State quantity and any asset-label needs; for procedures requiring Type 2 or another fiber mode, ask for the customized mapping instead of substituting this model.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.