MMC-24 APC to 3 x MTP-8 APC Breakout Cable, 24 Fibers, OM4

MMC-24 APC to 3 x MTP-8 APC Breakout Cable, 24 Fibers, OM4

The APC-to-APC version of the 24FMMCMTPOM4 breakout carries 24 OM4 fibers from one MMC APC female connector to three MTP-8 APC Elite female legs. All connection points use APC polish, and the fan-out follows factory harness polarity. It provides three eight-fiber multimode paths in one compact, factory-terminated assembly.

Product Highlights

  • MMC Female to MTP® Female, 24 Fibers
  • OM4 50/125µm, bend-insensitive fiber
  • MMC insertion loss ≤0.35dB, return loss ≥40/45dB (MMC/MTP®)
  • Harness Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number24FMMCMTPOM4
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Polish TypeAPC to APC
Glass FiberBend Insensitive Fiber
Fiber ModeOM4 50/125µm
Wavelength850/1300nm
Fiber Count24 Fibers
PolarityHarness Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥40/45dB (MMC/MTP®)
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-10 to 70°C (14 to 158°F)

A three-way fan-out with uniform polish

This cable is appropriate when both the MMC infrastructure and all three MTP destinations are designed for APC. The connectors are female and non-pinned, so pinned mates are required throughout. Before deployment, verify that the application truly calls for three eight-fiber branches and that no additional polarity reversal is introduced by the connected trunk or cassette.

Loss values for the complete optical path

The assembly is rated at 0.35dB maximum insertion loss, with at least 40dB return loss at MMC and 45dB at MTP APC. Use these connector-specific values when reviewing the passive link. OM4 performance at 850/1300nm supports multimode systems, but allowable distance and total connection count remain properties of the complete transceiver channel.

Installing and identifying three APC branches

Standard lengths are 1m (3ft), 2m (7ft) and 3m (10ft), with custom lengths in meters or feet. Because three similar MTP connectors leave one fan-out, branch labels are particularly valuable. Maintain gentle routing around the breakout body, inspect every ferrule and cap any branch that is not connected immediately.

Ordering and Factory Support

Specify 24FMMCMTPOM4 in the APC-to-APC three-leg configuration, with length and quantity. If the three branches terminate in different rack locations, provide the required leg arrangement and labeling rather than relying on a generic fan-out drawing.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.