MMC-24 APC to MTP-24 UPC Jumper, 24 Fibers, OM4

MMC-24 APC to MTP-24 UPC Jumper, 24 Fibers, OM4

The 24FMMCMTPOM4 jumper combines a 24-fiber MMC APC female interface with a 24-fiber MTP UPC female interface. This mixed-polish OM4 assembly is designed for channels that specifically require APC at the MMC side and UPC at the MTP side. It is not interchangeable with the APC-to-APC version, even though the two products share the same fiber count and connector families.

Product Highlights

  • MMC Female to MTP® Female, 24 Fibers
  • OM4 50/125µm, bend-insensitive fiber
  • MMC insertion loss ≤0.35dB, return loss ≥40/20dB (MMC/MTP®)
  • Jumper Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number24FMMCMTPOM4
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Polish TypeAPC to UPC
Glass FiberBend Insensitive Fiber
Fiber ModeOM4 50/125µm
Wavelength850/1300nm
Fiber Count24 Fibers
PolarityJumper Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥40/20dB (MMC/MTP®)
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-10 to 70°C (14 to 158°F)

Why the polish combination matters

APC and UPC end faces have different geometry and reflection behavior. They should never be forced together in a mating adapter. This jumper deliberately places APC on the MMC connector and UPC on the MTP Elite connector, so the surrounding channel must present the matching APC and UPC interfaces. Checking the polish at each end is as important as confirming 24-fiber compatibility.

Twenty-four fibers in a compact route

One 2.5mm OFNP jumper carries all 24 fibers, reducing cable bulk compared with twelve duplex cords. Both connectors are female and non-pinned, and factory jumper polarity controls the internal map. The MMC side provides at least 40dB return loss; the UPC MTP side is rated at 20dB minimum, with 0.35dB maximum insertion loss for the assembly.

Ordering and installing the correct version

Standard choices are 1m (3ft), 2m (7ft) and 3m (10ft), plus custom lengths in meters or feet. Identify this APC-to-UPC model clearly in rack documentation to distinguish it from APC-to-APC cords. During installation, inspect the ferrules, follow the key orientation and preserve the 7.5mm minimum optical-fiber bend radius around the MMC and MTP boots.

Ordering and Factory Support

Quote 24FMMCMTPOM4 and explicitly confirm the APC-to-UPC requirement, length and quantity. A simple port schedule showing the MMC and MTP mating interfaces will help prevent an accidental substitution with the APC-to-APC model.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.