MMC-16 to MMC-16 APC Jumper, 16 Fibers, OS2

MMC-16 to MMC-16 APC Jumper, 16 Fibers, OS2

The 16FMMCSMF jumper links two MMC-16 APC female interfaces with sixteen OS2 fibers in a single 2.5mm plenum cable. It is intended for dense single-mode patching where a compact connector footprint and controlled fiber mapping matter as much as optical loss. G.657.A1 glass supports routing through crowded managers without abandoning single-mode bend performance.

Product Highlights

  • MMC Female to MMC Female, 16 Fibers
  • OS2 9/125µm, G.657.A1
  • MMC insertion loss ≤0.35dB, return loss ≥60dB
  • Jumper Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number16FMMCSMF
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MMC Female (Non-Pinned)
Polish TypeAPC to APC
Glass FiberG.657.A1
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber Count16 Fibers
PolarityJumper Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥60dB
Attenuation at 1310nm≤0.35dB/km
Attenuation at 1550nm≤0.21dB/km
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-10 to 70°C (14 to 158°F)

Where this MMC-to-MMC jumper fits

Use this assembly between MMC adapter positions or other non-pinned MMC connection points in a structured cabling channel. Both ends are female, so the mating interface must provide the corresponding guide pins. It is not a generic replacement for an LC duplex cord: the sixteen fibers remain in one multi-fiber interface at each end, making the jumper most useful in parallel-optics and high-density panel environments.

Optical budget and routing details

Each MMC connection is specified at 0.35dB maximum insertion loss and at least 60dB return loss. Those values belong in the channel calculation alongside every adapter and trunk in the route. The cable has a 10mm minimum fiber bend radius and a 20/10D dynamic/static cable bend requirement; leave enough space behind the panel to meet those limits rather than forcing the boot into a sharp turn.

Lengths, polarity and incoming inspection

Standard lengths are 1m (3ft), 2m (7ft) and 3m (10ft), with other lengths available in meters or feet. This model uses jumper polarity, which should be checked against the complete link rather than assumed from the connector shape alone. Before mating, confirm APC-to-APC compatibility, inspect both ferrules and verify that the panel key orientation matches the connector.

Ordering and Factory Support

Quote 16FMMCSMF with the required length and quantity. For a non-standard route, include the desired length, labeling and packaging details; our team can also review gender and polarity against the panel schedule before production.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.