MMC-16 APC to 2 x MTP-8 APC Breakout Cable, 16 Fibers, OS2

MMC-16 APC to 2 x MTP-8 APC Breakout Cable, 16 Fibers, OS2

This OS2 breakout cable terminates a 16-fiber MMC APC female connector into two MTP-8 APC Elite female legs. It provides a direct single-mode fan-out for parallel-optics links that divide sixteen fibers into two eight-fiber interfaces. Factory-built harness polarity and labeled branches remove the need for a separate cassette and its additional mated connections.

Product Highlights

  • MMC Female to MTP® Female, 16 Fibers
  • OS2 9/125µm, G.657.A1
  • MMC insertion loss ≤0.35dB, return loss ≥60dB
  • Harness Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number16FMMCMTPSMF
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Polish TypeAPC to APC
Glass FiberG.657.A1
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber Count16 Fibers
PolarityHarness Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥60dB
Attenuation at 1310nm≤0.35dB/km
Attenuation at 1550nm≤0.21dB/km
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-10 to 70°C (14 to 158°F)

Mapping one MMC-16 into two MTP-8 legs

The MMC side concentrates all sixteen fibers in one VSFF housing, while each MTP branch carries eight fibers. This arrangement is appropriate only when the port and panel design expects the same two-way mapping. All three connectors are female and non-pinned, so the mating interfaces must provide guide pins. Verify the required APC polish on every leg before connecting the assembly.

Loss planning across three connection points

The specified insertion loss is 0.35dB maximum and return loss is at least 60dB. A complete link budget must include the MMC connection, the selected MTP branch connection and any adapters farther along the route. Keeping the two branch identities in the test report and rack records makes it easier to isolate a fault to one eight-fiber path.

Fan-out placement and standard lengths

Available lengths are 1m (3ft), 2m (7ft) and 3m (10ft), with custom lengths in meters or feet. Choose a length that lets the fan-out body rest in a supported area rather than hang from the MMC port. Route both MTP legs with gentle bends and avoid loading one branch differently from the other when dressing the cable.

Ordering and Factory Support

Request 16FMMCMTPSMF in the two-leg OS2 breakout configuration, stating overall length and quantity. If branch labels or unequal leg lengths are needed for a particular rack layout, include a fan-out drawing with the enquiry.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.