MMC-16 APC to 8 x LC UPC Harness Cable, 16 Fibers, OS2

MMC-16 APC to 8 x LC UPC Harness Cable, 16 Fibers, OS2

The 16FMMCLCSMF harness connects one MMC-16 APC female interface to eight LC UPC duplex connectors over OS2 fiber. All sixteen fibers are exposed as eight duplex pairs, providing a direct single-mode fan-out between MMC infrastructure and LC-based equipment or panels. This removes the intermediate cassette that would otherwise add hardware and another mated connection.

Product Highlights

  • MMC Female to LC UPC Duplex, 16 Fibers
  • OS2 9/125µm, G.657.A1
  • MMC insertion loss ≤0.35dB, return loss ≥60dB
  • LC insertion loss ≤0.2dB, return loss ≥50dB
  • Harness Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number16FMMCLCSMF
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BLC UPC Duplex
Polish TypeAPC to UPC
Glass FiberG.657.A1
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber Count16 Fibers
PolarityHarness Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
MMC Connector IL≤0.35dB
MMC Connector RL≥60dB
LC Connector IL≤0.2dB
LC Connector RL≥50dB
Attenuation at 1310nm≤0.35dB/km
Attenuation at 1550nm≤0.21dB/km
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-10 to 70°C (14 to 158°F)

Eight duplex legs with separate connector budgets

The MMC end is rated at 0.35dB maximum insertion loss and 60dB minimum return loss. Each LC UPC interface is specified at 0.2dB maximum insertion loss and 50dB minimum return loss. Keeping the two connector types separate in the specification helps engineers build an accurate loss budget for whichever duplex path is being tested.

Port mapping at the LC side

Eight similar LC duplex connectors require clear identification. Match each leg to the intended transmit and receive ports and preserve harness polarity through the rest of the channel. The MMC connector is female and non-pinned; verify the pinned mating interface and APC compatibility before insertion. LC UPC ends must likewise connect to UPC, not APC, adapters.

Length, fan-out position and fiber care

Standard overall lengths are 1m (3ft), 2m (7ft) and 3m (10ft), with custom lengths in meters or feet. Place the fan-out where the LC legs can reach their ports without side loading. G.657.A1 fiber has a 10mm minimum bend radius, while the complete cable also has dynamic and static bend requirements that should be observed during dressing.

Ordering and Factory Support

Order 16FMMCLCSMF with overall length and quantity, and include any LC leg-numbering scheme. For racks with multiple harnesses, customer-specific labels can tie each of the eight duplex legs directly to the port documentation.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.