16 Fibers MMC Female Type 1 Fiber Loopback Module, OM4

16 Fibers MMC Female Type 1 Fiber Loopback Module, OM4

This 16-fiber OM4 MMC loopback combines a female APC connector with Type 1 mapping for multimode optical port diagnostics. It loops transmit paths back to the receive side without requiring a remote device. G.657.A2 glass, a 100mm internal loop and a 250mm overall assembly provide a compact tool for production, commissioning and fault-isolation work.

Product Highlights

  • Fiber Type: OM4 50/125µm
  • Fiber Connector: MMC Female, APC
  • Glass Fiber: G.657.A2
  • Cable Jacket: Plenum (OFNP)
  • Fiber Count: 16 Fibers
  • Fiber Mapping: Type 1

Specifications

Part NumberLPM-OM4-16MMC
ManufacturerHT
Fiber TypeOM4 50/125µm
Fiber ConnectorMMC Female, APC
Glass FiberG.657.A2
Cable JacketPlenum (OFNP)
Fiber Count16 Fibers
Fiber MappingType 1
Insertion loss≤0.7dB
Return Loss≥60dB
Cable Outside Diameter (OD)2.5mm
Mating Durability50 cycles
Loop Length100mm (+0/-25mm)
Overall Length250mm (+50/-0mm)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Operation temperature0 to 60°C (32 to 140°F)
Storage Temperature-20 to 75°C (-4 to 167°F)

Matching the module to a multimode port

Use this loopback where the test setup explicitly calls for 16-fiber OM4 and Type 1 mapping. The MMC female APC interface must mate with the correct pinned APC port. Although OM4 and OS2 versions can share a connector family, their fiber characteristics differ, so the module should be labeled and stored distinctly in the test kit.

Using insertion loss in the test setup

The passive loop introduces up to 0.7dB insertion loss and has at least 60dB return loss. Check whether that attenuation is appropriate for the transmitter and receiver under test. A successful loop can support port-function checks and burn-in; a failed loop still requires systematic investigation of the module, connector cleanliness, mapping and active electronics.

Repeatable handling and cleanliness

The assembly is rated for 50 mating cycles and has a 2.5mm OFNP cable with a 7.5mm minimum optical-fiber bend radius. Do not use the short loop as a pull handle. Clean and inspect the ferrule before insertion, cap it after testing and keep the 100mm loop free from sharp edges or tightly weighted cable bundles.

Ordering and Factory Support

Specify LPM-OM4-16MMC for the 16-fiber OM4 Type 1 version, with quantity and required test-kit labels. Include the equipment test mapping if there is any uncertainty, so an alternative Type 2 custom module can be discussed instead.

 

Get a quick quote

Please write to sales@huihongfiber.com, we will reply as soon as possible.


Huihong Technologies

Add:6F,1st Bldg,ZYT industrial park, Shiyan area,Shenzhen,China
Email:info@huihongfiber.com
Tel: 86.755.61230063
Specialized fiber optic products manufacturer.

News and Exhibitions

Company news and exhibitions schedules for this year and next year. click here for details .
Thank you for visiting with Huihong Technologies.

Fiber Optic Applications

  • Fiber Optic Interconnect
  • Data centers
  • Military Fiber Optics
  • Medical Fiber Optics
  • Broadcast Fiber Optics

Customer Support

customer support
Thank you for the inquiry, please email sales@huihongfiber.com, we will reply to you asap.